Toward structure and metabolism of glycogen C<sub>1</sub>‐C<sub>6</sub> in humans at 7 T by localized <sup>13</sup>C MRS using low‐power bilevel broadband <sup>1</sup>H decoupling

This work aims to develop and implement a pulse-acquire sequence for three-dimensional (3D) single-voxel localized <sup>13</sup>C MRS in humans at 7 T, in conjunction with bilevel broadband <sup>1</sup>H decoupling, and to test its feasibility in vitro and in vivo in human calf muscle with emphasis on the detection of glycogen C<sub>1</sub>-C<sub>6</sub>. A localization scheme suitable for measuring fast-relaxing <sup>13</sup>C signals in humans at 7 T was developed and implemented using the outer volume suppression (OVS) and one-dimensional image selected in vivo spectroscopy (ISIS-1D) schemes, similar to that which was previously reported in humans at 4 T. The 3D <sup>13</sup>C localization scheme was followed by uniform <sup>13</sup>C adiabatic excitation, all complemented with an option for bilevel broadband <sup>1</sup>H decoupling to improve both <sup>13</sup>C sensitivity and spectral resolution at 7 T. The performance of the pulse-acquire sequence was investigated in vitro on phantoms and in vivo in the human calf muscle of three healthy volunteers, while measuring glycogen C<sub>1</sub>-C<sub>6</sub>. In addition, T<sub>1</sub> and T<sub>2</sub> of glycogen C<sub>1</sub>-C<sub>6</sub> were measured in vitro at 7 T, as well as T<sub>1</sub> of glycogen C<sub>1</sub> in vivo. The glycerol C<sub>2</sub> and C<sub>1,3</sub> lipid resonances were efficiently suppressed in vitro at 7 T using the OVS and ISIS-1D schemes, allowing distinct detection of glycogen C<sub>2</sub>-C<sub>6</sub>. While some glycerol remained in calf muscle in vivo, the intense lipid at 130 ppm was efficiently suppressed. The <sup>13</sup>C sensitivity and spectral resolution of glycogen C<sub>1</sub>-C<sub>6</sub> in vitro and glycogen C<sub>1</sub> in vivo were improved at 7 T using bilevel broadband <sup>1</sup>H decoupling. The T<sub>1</sub> and T<sub>2</sub> of glycogen C<sub>1</sub>-C<sub>6</sub> in vitro at 7 T were consistent compared with those at 8.5 T, while the T<sub>1</sub> of glycogen C<sub>1</sub> in vivo at 7 T resulted similar to that in vitro. Localized <sup>13</sup>C MRS is feasible in human calf muscle in vivo at 7 T, and this will allow further extension of this method for <sup>13</sup>C MRS measurements such as in the brain.

Authors

Institutions

Publication Details

Journal
NMR in Biomedicine
Published
2024-08-21
DOI
https://doi.org/10.1002/nbm.5241
Citations
2
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.81
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Toward structure and metabolism of glycogen C1‐C6 in humans at 7 T by localized 13C MRS using low‐power bilevel broadband 1H decoupling

Eulalia Serés Roig
2 citations
NMR in Biomedicine
Advanced MRI Techniques and Applications
0.81
article

Toward structure and metabolism of glycogen C1‐C6 in humans at 7 T by localized 13C MRS using low‐power bilevel broadband 1H decoupling

Eulalia Serés Roig
article en
2 citations

Abstract

This work aims to develop and implement a pulse-acquire sequence for three-dimensional (3D) single-voxel localized <sup>13</sup>C MRS in humans at 7 T, in conjunction with bilevel broadband <sup>1</sup>H decoupling, and to test its feasibility in vitro and in vivo in human calf muscle with emphasis on the detection of glycogen C<sub>1</sub>-C<sub>6</sub>. A localization scheme suitable for measuring fast-relaxing <sup>13</sup>C signals in humans at 7 T was developed and implemented using the outer volume suppression (OVS) and one-dimensional image selected in vivo spectroscopy (ISIS-1D) schemes, similar to that which was previously reported in humans at 4 T. The 3D <sup>13</sup>C localization scheme was followed by uniform <sup>13</sup>C adiabatic excitation, all complemented with an option for bilevel broadband <sup>1</sup>H decoupling to improve both <sup>13</sup>C sensitivity and spectral resolution at 7 T. The performance of the pulse-acquire sequence was investigated in vitro on phantoms and in vivo in the human calf muscle of three healthy volunteers, while measuring glycogen C<sub>1</sub>-C<sub>6</sub>. In addition, T<sub>1</sub> and T<sub>2</sub> of glycogen C<sub>1</sub>-C<sub>6</sub> were measured in vitro at 7 T, as well as T<sub>1</sub> of glycogen C<sub>1</sub> in vivo. The glycerol C<sub>2</sub> and C<sub>1,3</sub> lipid resonances were efficiently suppressed in vitro at 7 T using the OVS and ISIS-1D schemes, allowing distinct detection of glycogen C<sub>2</sub>-C<sub>6</sub>. While some glycerol remained in calf muscle in vivo, the intense lipid at 130 ppm was efficiently suppressed. The <sup>13</sup>C sensitivity and spectral resolution of glycogen C<sub>1</sub>-C<sub>6</sub> in vitro and glycogen C<sub>1</sub> in vivo were improved at 7 T using bilevel broadband <sup>1</sup>H decoupling. The T<sub>1</sub> and T<sub>2</sub> of glycogen C<sub>1</sub>-C<sub>6</sub> in vitro at 7 T were consistent compared with those at 8.5 T, while the T<sub>1</sub> of glycogen C<sub>1</sub> in vivo at 7 T resulted similar to that in vitro. Localized <sup>13</sup>C MRS is feasible in human calf muscle in vivo at 7 T, and this will allow further extension of this method for <sup>13</sup>C MRS measurements such as in the brain.

NMR in BiomedicineVol. 37(12)
École Polytechnique Fédérale de Lausanne (CH)
Zero hunger
Openalex Percentile: Top 26%
Advanced MRI Techniques and Applications
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.