Soft Single-Pole Reclosing Control for MMC-Connected AC Transmission Lines

In high-voltage systems, transmission lines typically use delayed-accelerated relays for fast reclosing during non-permanent faults. Yet, connecting these lines to MMCs can pose security risks due to the control strategy, while adaptive reclosing approaches only target permanent faults. To ensure security during non-permanent faults, single-pole reclosing is often blocked, albeit at the expense of parallel system stability. This study proposes a soft single-pole reclosing control to address this challenge. First, a mathematical analysis identifies the root cause of reclosing inrush, considering two controllable variables among the four influencing factors. These variables are selected to optimize both control dimensions and performance. Then, deep reinforcement learning is introduced to drive the MMC during open-phase operation, which completes a comprehensive regulation within several control cycles. Simulation and experimental studies validate the performance, indicating that the SSRC not only limits the reclosing inrush but also keeps the power system's normal operating.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Power Delivery
Published
2024-08-21
DOI
https://doi.org/10.1109/tpwrd.2024.3447084
Citations
3
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.63
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Soft Single-Pole Reclosing Control for MMC-Connected AC Transmission Lines

Ning Tong, Yu Wang, Jun Li, Guiyuan Li et al.
3 citations
IEEE Transactions on Power Delivery
HVDC Systems and Fault Protection
0.63
article

Soft Single-Pole Reclosing Control for MMC-Connected AC Transmission Lines

Ning Tong, Yu Wang, Jun Li, Guiyuan Li, Runbin Cao, Weihuang Huang
article en
3 citations

Abstract

In high-voltage systems, transmission lines typically use delayed-accelerated relays for fast reclosing during non-permanent faults. Yet, connecting these lines to MMCs can pose security risks due to the control strategy, while adaptive reclosing approaches only target permanent faults. To ensure security during non-permanent faults, single-pole reclosing is often blocked, albeit at the expense of parallel system stability. This study proposes a soft single-pole reclosing control to address this challenge. First, a mathematical analysis identifies the root cause of reclosing inrush, considering two controllable variables among the four influencing factors. These variables are selected to optimize both control dimensions and performance. Then, deep reinforcement learning is introduced to drive the MMC during open-phase operation, which completes a comprehensive regulation within several control cycles. Simulation and experimental studies validate the performance, indicating that the SSRC not only limits the reclosing inrush but also keeps the power system's normal operating.

IEEE Transactions on Power DeliveryVol. 39(5)
Guangdong University of Technology (CN), China Southern Power Grid (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 32%
HVDC Systems and Fault Protection
0.63
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Soft Single-Pole Reclosing Control for MMC-Connected AC Transmission Lines — Ning Tong, Yu Wang, et al. · IEEE Transactions on Power Delivery (2024) | TGRS Research Map | TGRS