A Compact, Single Stage, >1 kV Medium-Voltage Line Impedance Stabilization Network

This article presents the design of a single-phase, single-stage line impedance stabilization network (LISN) for medium-voltage (MV) applications. More than 1 kV rated wide-bandgap (WBG) power semiconductor switches are increasingly utilized in new, emerging power electronics energy systems to improve power density and efficiency. However, due to inherently fast-switching speeds, WBG switch modules emit considerable electromagnetic interference (EMI) (e.g., common mode or differential mode). State-of-the-art offers standardized LISN solutions to validate and certify the new energy system for electromagnetic compatibility. However, most are for low voltage applications (i.e., < 1 kV). MV LISNs (i.e., > 1 kV) are rare until recently and literature does not provide sufficient guidelines for designing and characterizing such devices. It has been a critical challenge for many scientists and engineers to reliably certify the emerging MV energy systems (e.g., electric ships and aircraft). This article addresses such a technology gap. Specifically, a CISPR 16-1-2 compliant 50 Ω/50 µH LISN with 1.5 kV, 75 A and 30 MHz measurement capability has been proposed. Detailed performance study versus non-linear parasitic parameters variations in MV inductors and capacitors have been done. Based on new understandings, novel techniques to intuitively mitigate unwanted parasitic have been proposed to develop the proposed LISN successfully. Thorough characterization of important LISN parameters are presented and factors influencing them are analyzed. A rigorous analysis, experimental tests, and in-depth comparisons over state-of-the-art have been made to validate the effectiveness. This is done through the state-of-the-art 300 kVA MV EMI testbed.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Power Electronics
Published
2024-08-21
DOI
https://doi.org/10.1109/tpel.2024.3447568
Citations
2
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.66

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Compact, Single Stage, >1 kV Medium-Voltage Line Impedance Stabilization Network

Mostak Mohammad, Seungdeog Choi, Ashik Amin, Tahmid Ibne Mannan
2 citations
IEEE Transactions on Power Electronics
Power Systems Fault Detection
0.66
article

A Compact, Single Stage, >1 kV Medium-Voltage Line Impedance Stabilization Network

Mostak Mohammad, Seungdeog Choi, Ashik Amin, Tahmid Ibne Mannan
article en
2 citations

Abstract

This article presents the design of a single-phase, single-stage line impedance stabilization network (LISN) for medium-voltage (MV) applications. More than 1 kV rated wide-bandgap (WBG) power semiconductor switches are increasingly utilized in new, emerging power electronics energy systems to improve power density and efficiency. However, due to inherently fast-switching speeds, WBG switch modules emit considerable electromagnetic interference (EMI) (e.g., common mode or differential mode). State-of-the-art offers standardized LISN solutions to validate and certify the new energy system for electromagnetic compatibility. However, most are for low voltage applications (i.e., < 1 kV). MV LISNs (i.e., > 1 kV) are rare until recently and literature does not provide sufficient guidelines for designing and characterizing such devices. It has been a critical challenge for many scientists and engineers to reliably certify the emerging MV energy systems (e.g., electric ships and aircraft). This article addresses such a technology gap. Specifically, a CISPR 16-1-2 compliant 50 Ω/50 µH LISN with 1.5 kV, 75 A and 30 MHz measurement capability has been proposed. Detailed performance study versus non-linear parasitic parameters variations in MV inductors and capacitors have been done. Based on new understandings, novel techniques to intuitively mitigate unwanted parasitic have been proposed to develop the proposed LISN successfully. Thorough characterization of important LISN parameters are presented and factors influencing them are analyzed. A rigorous analysis, experimental tests, and in-depth comparisons over state-of-the-art have been made to validate the effectiveness. This is done through the state-of-the-art 300 kVA MV EMI testbed.

IEEE Transactions on Power ElectronicsVol. 39(12)
Oak Ridge National Laboratory (US), Kohler (United States) (US), Mississippi State University (US)
Office of Naval Research
Affordable and clean energy
Openalex Percentile: Top 31%
Power Systems Fault Detection
0.66
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.