A semi-active adaptive pneumatic vibration isolator based on frequency response analysis and nonlinear control

In this work, an adaptive nonlinear error feedback controller based on fuzzy state observer is proposed to a novel rubber pneumatic vibration isolator (PVI) system. First, a novel rubber PVI system is designed and developed. Harmonic balance method is applied to establish the dynamic model of the PVI system, so as to analyze the frequency response characteristics of the system. Second, to improve the PVI performance in low-frequency vibration, a nonlinear state error feedback control system based on fuzzy state observer is designed for the active PVI system. Furthermore, the experiment system is established. Finally, through the experimental comparison under 5 Hz, 7 Hz, 20 Hz, and 40 Hz, an adaptive PVI strategy is proposed. The experimental results demonstrate that the adaptive PVI shows better performance in vibration isolation.

Authors

Institutions

Publication Details

Journal
Journal of Vibration and Control
Published
2024-08-20
DOI
https://doi.org/10.1177/10775463241269789
Citations
1
Primary Topic
Vibration Control and Rheological Fluids
Type
article
Field-Weighted Citation Impact
0.26

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A semi-active adaptive pneumatic vibration isolator based on frequency response analysis and nonlinear control

Shaofeng Xu, Zhibo Sun, Jifan Wu, Yixuan Wang et al.
1 citations
Journal of Vibration and Control
Vibration Control and Rheological Fluids
0.26
article

A semi-active adaptive pneumatic vibration isolator based on frequency response analysis and nonlinear control

Shaofeng Xu, Zhibo Sun, Jifan Wu, Yixuan Wang, Yan Shi
article en
1 citations

Abstract

In this work, an adaptive nonlinear error feedback controller based on fuzzy state observer is proposed to a novel rubber pneumatic vibration isolator (PVI) system. First, a novel rubber PVI system is designed and developed. Harmonic balance method is applied to establish the dynamic model of the PVI system, so as to analyze the frequency response characteristics of the system. Second, to improve the PVI performance in low-frequency vibration, a nonlinear state error feedback control system based on fuzzy state observer is designed for the active PVI system. Furthermore, the experiment system is established. Finally, through the experimental comparison under 5 Hz, 7 Hz, 20 Hz, and 40 Hz, an adaptive PVI strategy is proposed. The experimental results demonstrate that the adaptive PVI shows better performance in vibration isolation.

Journal of Vibration and ControlVol. 31(15-16)
Inner Mongolia University of Science and Technology (CN), Beihang University (CN)
National Natural Science Foundation of China, National Key Research and Development Program of China
Affordable and clean energy
Openalex Percentile: Top 46%
Vibration Control and Rheological Fluids
0.26
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.