Use of real-time electronic extremity dosimeters for monitoring and optimisation of radiopharmacy technique

Radiopharmacy staff members are subject to extremity radiation doses, particularly to the fingertips. Dosemeters, such as, thermoluminescent detectors (TLDs) are currently used for monitoring fingertip doses. This study aimed to use real-time dosemeters to monitor radiopharmacy extremity doses to identify specific procedural steps associated with higher fingertip doses and, subsequently, reduce dose through promotion of optimised radiation protection practises. Five radiopharmacy operators were monitored using an ED3 active extremity dosemeter with a detector attached to each tip of the index fingers. Dose rate and accumulated dose data were matched to the handled radioactivity data, of<sup>99m</sup>Tc-labelled radiopharmaceuticals only, with the dose per activity (<i>μ</i>Sv MBq<sup>-1</sup>) calculated for each step. Once baseline dose data was established, an educational session identified technique adjustments toward improved radiation protection. A subsequent monitored session was undertaken with the dose data compared to quantify changes in operator doses. Radiopharmacy steps which significantly contributed to extremity doses were identified. The average accumulated dose per activity across all procedural steps for the<sup>99m</sup>Tc-labelled radiopharmaceuticals for all operators before the educational session was 0.042 ± 0.045<i>μ</i>Sv MBq<sup>-1</sup>and 0.042 ± 0.041<i>μ</i>Sv MBq<sup>-1</sup>(<i>n</i>= 89) for non-dominant and dominant index fingertips, respectively, and 0.030 ± 0.044<i>μ</i>Sv MBq<sup>-1</sup>and 0.031 ± 0.032<i>μ</i>Sv MBq<sup>-1</sup>(<i>n</i>= 97), respectively, afterwards. Overall, there was an average 40.7% reduction in the total extremity dose received after the educational session. Real-time electronic extremity dosemeters for monitoring radiopharmacy extremity dose presented as a useful tool for incorporation into radiation protection education and training, towards optimised radiopharmacy technique.

Authors

Institutions

Publication Details

Journal
Journal of Radiological Protection
Published
2024-08-21
DOI
https://doi.org/10.1088/1361-6498/ad71d9
Primary Topic
Radiopharmaceutical Chemistry and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Use of real-time electronic extremity dosimeters for monitoring and optimisation of radiopharmacy technique

Jackie McCavana, Claire Kenneally, Seán Cournane, Linda Tutty et al.
Journal of Radiological Protection
Radiopharmaceutical Chemistry and Applications
article

Use of real-time electronic extremity dosimeters for monitoring and optimisation of radiopharmacy technique

Jackie McCavana, Claire Kenneally, Seán Cournane, Linda Tutty, Julie Lucey, D. Maguire, Laura Harris
article en

Abstract

Radiopharmacy staff members are subject to extremity radiation doses, particularly to the fingertips. Dosemeters, such as, thermoluminescent detectors (TLDs) are currently used for monitoring fingertip doses. This study aimed to use real-time dosemeters to monitor radiopharmacy extremity doses to identify specific procedural steps associated with higher fingertip doses and, subsequently, reduce dose through promotion of optimised radiation protection practises. Five radiopharmacy operators were monitored using an ED3 active extremity dosemeter with a detector attached to each tip of the index fingers. Dose rate and accumulated dose data were matched to the handled radioactivity data, of<sup>99m</sup>Tc-labelled radiopharmaceuticals only, with the dose per activity (<i>μ</i>Sv MBq<sup>-1</sup>) calculated for each step. Once baseline dose data was established, an educational session identified technique adjustments toward improved radiation protection. A subsequent monitored session was undertaken with the dose data compared to quantify changes in operator doses. Radiopharmacy steps which significantly contributed to extremity doses were identified. The average accumulated dose per activity across all procedural steps for the<sup>99m</sup>Tc-labelled radiopharmaceuticals for all operators before the educational session was 0.042 ± 0.045<i>μ</i>Sv MBq<sup>-1</sup>and 0.042 ± 0.041<i>μ</i>Sv MBq<sup>-1</sup>(<i>n</i>= 89) for non-dominant and dominant index fingertips, respectively, and 0.030 ± 0.044<i>μ</i>Sv MBq<sup>-1</sup>and 0.031 ± 0.032<i>μ</i>Sv MBq<sup>-1</sup>(<i>n</i>= 97), respectively, afterwards. Overall, there was an average 40.7% reduction in the total extremity dose received after the educational session. Real-time electronic extremity dosemeters for monitoring radiopharmacy extremity dose presented as a useful tool for incorporation into radiation protection education and training, towards optimised radiopharmacy technique.

Journal of Radiological ProtectionVol. 44(3)
Food for Health Ireland (IE), St. Vincent's University Hospital (IE)
Openalex Percentile: Top 78%
Radiopharmaceutical Chemistry and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.