Effect of Plate Length on Construct Stiffness and Strain in a Synthetic Short-Fragment Fracture Gap Model Stabilized with a 3.5-mm Locking Compression Plate
Incremental increases in construct stiffness and incremental decreases in plate strain were only identified when comparing 6-hole, 8-hole, and 10-hole plates to 12-hole plates, and 6-hole to 12-hole plates, respectively. Strain on the bone model showed an incremental decrease when comparing 6-hole to 10-hole and 12-hole plates. A long plate offered biomechanical advantages of increased construct stiffness and reduced plate and bone model strain, over a short plate in this in vitro model.
Authors
- Giselle Hosgood (ORCID: https://orcid.org/0000-0002-8851-8597)
- Robert E. Day (ORCID: https://orcid.org/0000-0003-3442-2298)
- Mark Glyde (ORCID: https://orcid.org/0000-0003-1433-7694)
- Alex Hayes (ORCID: https://orcid.org/0000-0002-5465-2253)
- Fabian N. Trefny
Institutions
- Murdoch University (AU)
- Royal Perth Hospital (AU)
Publication Details
- Journal
- Veterinary and Comparative Orthopaedics and Traumatology
- Published
- 2024-08-21
- DOI
- https://doi.org/10.1055/s-0044-1789263
- Citations
- 2
- Primary Topic
- Fatigue and fracture mechanics
- Type
- article
- Field-Weighted Citation Impact
- 0.54