Refining penalty parameter selection in whole-body PET image reconstruction for lung cancer patients using the cross-validation log-likelihood method
<i>Objective.</i>Penalty parameters in penalized likelihood positron emission tomography (PET) reconstruction are typically determined empirically. The cross-validation log-likelihood (CVLL) method has been introduced to optimize these parameters by maximizing a CVLL function, which assesses the likelihood of reconstructed images using one subset of a list-mode dataset based on another subset. This study aims to validate the efficacy of the CVLL method in whole-body imaging for cancer patients using a conventional clinical PET scanner.<i>Approach.</i>Fifteen lung cancer patients were injected with 243.7 ± 23.8 MBq of [<sup>18</sup>F]FDG and underwent a 22 min PET scan on a Biograph mCT PET/CT scanner, starting at 60 ± 5 min post-injection. The PET list-mode data were partitioned by subsampling without replacement, with 20 minutes of data for image reconstruction using an in-house ordered subset expectation maximization algorithm and the remaining 2 minutes of data for cross-validation. Two penalty parameters, penalty strength<i>β</i>and Fair penalty function parameter<i>δ</i>, were subjected to optimization. Whole-body images were reconstructed, and CVLL values were computed across various penalty parameter combinations. The optimal image corresponding to the maximum CVLL value was selected by a grid search for each patient.<i>Main results.</i>The<i>δ</i>value required to maximize the CVLL value was notably small (⩽10<sup>-6</sup>in this study). The influences of voxel size and scan duration on image optimization were investigated. A correlation analysis revealed a significant inverse relationship between optimal<i>β</i>and scan count level, with a correlation coefficient of -0.68 (<i>p</i>-value = 3.5 × 10<sup>-5</sup>). The optimal images selected by the CVLL method were compared with those chosen by two radiologists based on their diagnostic preferences. Differences were observed in the selection of optimal images.<i>Significance.</i>This study demonstrates the feasibility of incorporating the CVLL method into routine imaging protocols, potentially allowing for a wide range of combinations of injected radioactivity amounts and scan durations in modern PET imaging.
Authors
- Jinyi Qi (ORCID: https://orcid.org/0000-0002-5428-0322)
- Lorenzo Nardo (ORCID: https://orcid.org/0000-0002-0266-2708)
- Q. S. Wang (ORCID: https://orcid.org/0000-0002-5268-1085)
- Hande Nalbant (ORCID: https://orcid.org/0000-0002-8600-6707)
- Simon R. Cherry (ORCID: https://orcid.org/0000-0002-0155-5644)
- Ramsey Derek Badawi (ORCID: https://orcid.org/0000-0002-9769-0292)
- Yasser G. Abdelhafez (ORCID: https://orcid.org/0000-0002-1989-3094)
- Reimund Bayerlein (ORCID: https://orcid.org/0000-0002-5493-7355)
- Benjamin A. Spencer
Institutions
- University of California Davis Medical Center (US)
- UC Davis Health (US)
- University of California, Davis (US)
- Assiut University (EG)
Publication Details
- Journal
- Physics in Medicine and Biology
- Published
- 2024-08-21
- DOI
- https://doi.org/10.1088/1361-6560/ad7222
- Citations
- 1
- Primary Topic
- Medical Imaging Techniques and Applications
- Type
- article
- Field-Weighted Citation Impact
- 0.40
Funders
- National Cancer Institute