Contamination-Free Reference Electrode Using Prussian Blue for Small Oxygen Sensors

In recent years, significant attention has been directed toward advancing compact, point-of-care testing (POCT) devices to better deliver patient care and alleviate the burden on the medical care system. Common POCTs, such as blood oxygen sensors, leverage electrochemical sensing in their design. However, conventional electrochemical devices typically use Ag/AgCl reference electrodes, which are likely to release trace amounts of silver ions that contaminate the working electrode, causing rapid deterioration of the devices. This study proposes an effective reference electrode using graphene-coated porous silica spheres (G/PSS) with embedded Prussian blue (PB), denoted PB/G/PSS, designed specifically for small oxygen sensors. PB is a redox species that is an improvement over Ag/AgCl since it is significantly less water-soluble than AgCl. Since PB is an insulator, we dispersed PB in G/PSS, well-conductive mesoporous matrices, to ensure contact between PB clusters and the electrolytes. Moreover, the monodispersed, spherically shaped PB/G/PSS is an advantageous medium for fabricating POCT devices by screen printing. In this study, the open-circuit potential of the PB/G/PSS electrode remained stable within 30 mV for 31 days. The small oxygen sensor assembled through screen printing using PB/G/PSS demonstrated stable operation for several days or more. In contrast, a similar sensor with Ag/AgCl reference electrode rapidly deteriorated within a day. This PB/G/PSS reference electrode with improved stability is expected to be an excellent alternative to the Ag/AgCl system for small electrochemical-based POCT devices.

Authors

Institutions

Publication Details

Journal
ACS Applied Materials & Interfaces
Published
2024-08-20
DOI
https://doi.org/10.1021/acsami.4c05103
Citations
5
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
1.44

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Contamination-Free Reference Electrode Using Prussian Blue for Small Oxygen Sensors

Hirotomo Nishihara, Yasuhisa Hasegawa, Kritin Pirabul, Norihito Hiyoshi et al.
5 citations
ACS Applied Materials & Interfaces
Analytical Chemistry and Sensors
1.44
article

Contamination-Free Reference Electrode Using Prussian Blue for Small Oxygen Sensors

Hirotomo Nishihara, Yasuhisa Hasegawa, Kritin Pirabul, Norihito Hiyoshi, Akiko Yoshida, Takeharu Yoshii, Yuka Minegishi, Shunsuke Fujii, Zheng‐Ze Pan, Kota Takeda, Tetsuji Itoh, Yukinori Noguchi, Mutsuhiro Ito, Kenichi Izawa
article en
5 citations

Abstract

In recent years, significant attention has been directed toward advancing compact, point-of-care testing (POCT) devices to better deliver patient care and alleviate the burden on the medical care system. Common POCTs, such as blood oxygen sensors, leverage electrochemical sensing in their design. However, conventional electrochemical devices typically use Ag/AgCl reference electrodes, which are likely to release trace amounts of silver ions that contaminate the working electrode, causing rapid deterioration of the devices. This study proposes an effective reference electrode using graphene-coated porous silica spheres (G/PSS) with embedded Prussian blue (PB), denoted PB/G/PSS, designed specifically for small oxygen sensors. PB is a redox species that is an improvement over Ag/AgCl since it is significantly less water-soluble than AgCl. Since PB is an insulator, we dispersed PB in G/PSS, well-conductive mesoporous matrices, to ensure contact between PB clusters and the electrolytes. Moreover, the monodispersed, spherically shaped PB/G/PSS is an advantageous medium for fabricating POCT devices by screen printing. In this study, the open-circuit potential of the PB/G/PSS electrode remained stable within 30 mV for 31 days. The small oxygen sensor assembled through screen printing using PB/G/PSS demonstrated stable operation for several days or more. In contrast, a similar sensor with Ag/AgCl reference electrode rapidly deteriorated within a day. This PB/G/PSS reference electrode with improved stability is expected to be an excellent alternative to the Ag/AgCl system for small electrochemical-based POCT devices.

ACS Applied Materials & InterfacesVol. 16(38)
University of Tsukuba (JP), Tohoku University (JP), Advanced Institute of Materials Science (JP), Hodogaya Chemical (Japan) (JP), National Institute of Advanced Industrial Science and Technology (JP)
Adaptable and Seamless Technology Transfer Program through Target-Driven R and D, Strategic International Collaborative Research Program
Openalex Percentile: Top 21%
Analytical Chemistry and Sensors
1.44
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.