Multi-modal transformer architecture for medical image analysis and automated report generation

Medical practitioners examine medical images, such as X-rays, write reports based on the findings, and provide conclusive statements. Manual interpretation of the results and report generation by examiners are time-consuming processes that lead to potential delays in diagnosis. We propose an automated report generation model for medical images leveraging an encoder-decoder architecture. Our model utilizes transformer architectures, including Vision Transformer (ViT) and its variants like Data Efficient Image Transformer (DEiT) and BERT pre-training image transformer (BEiT), as an encoder. These transformers are adapted for processing to extract and gain visual information from medical images. Reports are transformed into text embeddings, and the Generative Pre-trained Transformer (GPT2) model is used as a decoder to generate medical reports. Our model utilizes a cross-attention mechanism between the vision transformer and GPT2, which enables it to create detailed and coherent medical reports based on the visual information extracted by the encoder. In our model, we have extended the report generation with general knowledge, which is independent of the inputs and provides a comprehensive report in a broad sense. We conduct our experiments on the Indiana University X-ray dataset to demonstrate the effectiveness of our models. Generated medical reports from the model are evaluated using word overlap metrics such as Bleu scores, Rouge-L, retrieval augmentation answer correctness, and similarity metrics such as skip thought cs, greedy matching, vector extrema, and RAG answer similarity. Results show that our model is performing better than the recurrent models in terms of report generation, answer similarity, and word overlap metrics. By automating the report generation process and incorporating advanced transformer architectures and general knowledge, our approach has the potential to significantly improve the efficiency and accuracy of medical image analysis and report generation.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2024-08-20
DOI
https://doi.org/10.1038/s41598-024-69981-5
Citations
37
Primary Topic
Image Retrieval and Classification Techniques
Type
article
Field-Weighted Citation Impact
9.22

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multi-modal transformer architecture for medical image analysis and automated report generation

S. Shridevi, Daehan Won, Santhosh Raminedi
37 citations
Scientific Reports
Image Retrieval and Classification Techniques
9.22
article

Multi-modal transformer architecture for medical image analysis and automated report generation

S. Shridevi, Daehan Won, Santhosh Raminedi
article en
37 citations

Abstract

Medical practitioners examine medical images, such as X-rays, write reports based on the findings, and provide conclusive statements. Manual interpretation of the results and report generation by examiners are time-consuming processes that lead to potential delays in diagnosis. We propose an automated report generation model for medical images leveraging an encoder-decoder architecture. Our model utilizes transformer architectures, including Vision Transformer (ViT) and its variants like Data Efficient Image Transformer (DEiT) and BERT pre-training image transformer (BEiT), as an encoder. These transformers are adapted for processing to extract and gain visual information from medical images. Reports are transformed into text embeddings, and the Generative Pre-trained Transformer (GPT2) model is used as a decoder to generate medical reports. Our model utilizes a cross-attention mechanism between the vision transformer and GPT2, which enables it to create detailed and coherent medical reports based on the visual information extracted by the encoder. In our model, we have extended the report generation with general knowledge, which is independent of the inputs and provides a comprehensive report in a broad sense. We conduct our experiments on the Indiana University X-ray dataset to demonstrate the effectiveness of our models. Generated medical reports from the model are evaluated using word overlap metrics such as Bleu scores, Rouge-L, retrieval augmentation answer correctness, and similarity metrics such as skip thought cs, greedy matching, vector extrema, and RAG answer similarity. Results show that our model is performing better than the recurrent models in terms of report generation, answer similarity, and word overlap metrics. By automating the report generation process and incorporating advanced transformer architectures and general knowledge, our approach has the potential to significantly improve the efficiency and accuracy of medical image analysis and report generation.

Scientific ReportsVol. 14(1)
Binghamton University (US), Vellore Institute of Technology University (IN)
Vellore Institute of Technology, Chennai, VIT University
Openalex Percentile: Top 1%
Image Retrieval and Classification Techniques
9.22
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.