Non-enzymatic detection of 17β-estradiol in real samples using PANI@CeO2 nanocomposite

Herein, we developed a non-enzymatic biosensing platform using polyaniline (PANI) polymer matrix grafted with CeO2. The one-pot synthesized nanocomposite has been used for the detection of 17β-estradiol (E2). The homogeneous distribution of CeO2 onto the PANI matrix leads to an increase in surface area, conductivity, and effectiveness of the synthesized nanocomposite PANI@CeO2. The PANI@CeO2 nanocomposite was characterized using structural and morphological techniques. Further, the electrode fabrication was performed electrophoretically by depositing the PANI@CeO2 nanocomposite onto the ITO electrode. The PANI@CeO2/ITO showed enhanced electrochemical behavior as compared to PANI/ITO. Detection of E2 was carried out using the differential pulse voltametric technique (DPV). Linearity has been observed through the detection range of 1 µM–100 µM with LOD = 2.15 µM. The developed biosensor has been found to be stable and selective towards E2. It has been successfully utilized for the detection of E2 in real samples like tap water and human urine samples. Thus, this research encourages its use for more applications in clinical diagnosis and biomedical sciences.

Authors

Institutions

Publication Details

Journal
Characterization and Application of Nanomaterials
Published
2024-08-19
DOI
https://doi.org/10.24294/can.v7i2.4768
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Non-enzymatic detection of 17β-estradiol in real samples using PANI@CeO2 nanocomposite

Sakshi Verma, Devendra Kumar, Tanu Rajput, Aditya Dam
Characterization and Application of Nanomaterials
Electrochemical sensors and biosensors
article

Non-enzymatic detection of 17β-estradiol in real samples using PANI@CeO2 nanocomposite

Sakshi Verma, Devendra Kumar, Tanu Rajput, Aditya Dam
article en

Abstract

Herein, we developed a non-enzymatic biosensing platform using polyaniline (PANI) polymer matrix grafted with CeO2. The one-pot synthesized nanocomposite has been used for the detection of 17β-estradiol (E2). The homogeneous distribution of CeO2 onto the PANI matrix leads to an increase in surface area, conductivity, and effectiveness of the synthesized nanocomposite PANI@CeO2. The PANI@CeO2 nanocomposite was characterized using structural and morphological techniques. Further, the electrode fabrication was performed electrophoretically by depositing the PANI@CeO2 nanocomposite onto the ITO electrode. The PANI@CeO2/ITO showed enhanced electrochemical behavior as compared to PANI/ITO. Detection of E2 was carried out using the differential pulse voltametric technique (DPV). Linearity has been observed through the detection range of 1 µM–100 µM with LOD = 2.15 µM. The developed biosensor has been found to be stable and selective towards E2. It has been successfully utilized for the detection of E2 in real samples like tap water and human urine samples. Thus, this research encourages its use for more applications in clinical diagnosis and biomedical sciences.

Characterization and Application of NanomaterialsVol. 7(2)
Delhi Technological University (IN)
Clean water and sanitation
Openalex Percentile: Top 89%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Non-enzymatic detection of 17β-estradiol in real samples using PANI@CeO2 nanocomposite — Sakshi Verma, Devendra Kumar, et al. · Characterization and Application of Nanomaterials (2024) | TGRS Research Map | TGRS