Defining the Spatial Resolution of Analyte Recovery during Microperfusion-Based Sampling of Brain Parenchyma

The unique architecture of the brain and the blood-brain barrier imposes challenges for the measurement of parenchyma-derived biomarkers that prevent sufficient understanding of transient neuropathogenic processes. One solution to this challenge is direct sampling of brain interstitial fluid via implanted microperfusion probes. Seeking to understand spatial limitations to microperfusion in the brain, we employed computational fluid dynamics modeling and empirical recovery of fluorescently labeled dextrans in an animal model. We found that dextrans were successfully recovered via microperfusion over a 6 h sampling period, especially at probes implanted 2 mm from the dextran infusion point relative to probes implanted 5 mm from the injection site. Experimental recovery was consistently around 1% of simulated, suggesting that this parameter can be used to set practical limits on the maximal tissue concentration of proteins measured in microperfusates and on the spatial domain sampled by our multimodal microperfusion probe.

Authors

Institutions

Publication Details

Journal
ACS Chemical Neuroscience
Published
2024-08-19
DOI
https://doi.org/10.1021/acschemneuro.4c00410
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Defining the Spatial Resolution of Analyte Recovery during Microperfusion-Based Sampling of Brain Parenchyma

Terry C. Burns, Jonghoon Choi, Kevin E. Bennet, Charles L. Howe et al.
ACS Chemical Neuroscience
Advanced MRI Techniques and Applications
article

Defining the Spatial Resolution of Analyte Recovery during Microperfusion-Based Sampling of Brain Parenchyma

Terry C. Burns, Jonghoon Choi, Kevin E. Bennet, Charles L. Howe, Jamie J. Van Gompel, Inyong Kim, Gregory A. Worrell, Su-Youne Chang, Luke A Stangler, Abbas Z. Kouzani
article en

Abstract

The unique architecture of the brain and the blood-brain barrier imposes challenges for the measurement of parenchyma-derived biomarkers that prevent sufficient understanding of transient neuropathogenic processes. One solution to this challenge is direct sampling of brain interstitial fluid via implanted microperfusion probes. Seeking to understand spatial limitations to microperfusion in the brain, we employed computational fluid dynamics modeling and empirical recovery of fluorescently labeled dextrans in an animal model. We found that dextrans were successfully recovered via microperfusion over a 6 h sampling period, especially at probes implanted 2 mm from the dextran infusion point relative to probes implanted 5 mm from the injection site. Experimental recovery was consistently around 1% of simulated, suggesting that this parameter can be used to set practical limits on the maximal tissue concentration of proteins measured in microperfusates and on the spatial domain sampled by our multimodal microperfusion probe.

ACS Chemical NeuroscienceVol. 15(17)
Mayo Clinic (US), Deakin University (AU)
Mayo Clinic, National Institute of Neurological Disorders and Stroke
Zero hunger
Openalex Percentile: Top 78%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.