Harmonic errors of a 9.4 T all-REBCO NMR magnet affected by screening current and geometric inconsistency of coated conductors

REBa <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mmultiscripts><mml:mrow></mml:mrow> <mml:mn>2</mml:mn> <mml:mrow></mml:mrow></mml:mmultiscripts> </mml:math> Cu <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mmultiscripts><mml:mrow></mml:mrow> <mml:mn>3</mml:mn> <mml:mrow></mml:mrow></mml:mmultiscripts> </mml:math> O <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mmultiscripts><mml:mrow></mml:mrow> <mml:mrow><mml:mn>7</mml:mn> <mml:mo>-</mml:mo> <mml:mtext>x</mml:mtext></mml:mrow> <mml:mrow></mml:mrow></mml:mmultiscripts> </mml:math> (REBCO, RE = rare earth)-coated conductor is a competitive option in terms of current-carrying capacity and high-stress durability in developing high-field magnets for nuclear magnetic resonance (NMR) research. Meanwhile, a technical challenge in utilizing a stand-alone REBCO NMR magnet is an unexpected difference in the field uniformity between the designed and measured values after being constructed and charged, i.e., harmonic errors. Bortot et al., and Li et al., reported analytic evidence of the related issue. However, sufficient research has not yet been conducted, so evidence should be supplemented further. Here we report harmonic errors due to screening current and inconsistent conductor thickness, confirmed by a 400 MHz <sup>1</sup>H NMR magnet development project. The magnet was first charged up to its operating current, and then multiple overcharge-discharge cycles were applied, which was an empirically optimized operation protocol. A field mapping device obtained magnetic fields at designated locations in the room-temperature bore. The result showed over 100 ppm field uniformity difference between designed and measured values. A simulation model was developed considering screening current and inconsistent conductor thickness for reproducing the field distribution. Comparison of voltages and fields between simulation and measurement validated the model. Further analysis of the overcharge-discharge effect on harmonic errors demonstrated that even and odd-order harmonics are mainly attributed to screening current and geometric inconsistency while confirming the limitation of the screening current mitigation effect. Hence, we concluded that the desirable requirement of the sub-ppm level field uniformity generation might be barely possible with the current REBCO NMR magnet design approach.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2024-08-19
DOI
https://doi.org/10.1038/s41598-024-68607-0
Citations
3
Primary Topic
NMR spectroscopy and applications
Type
article
Field-Weighted Citation Impact
1.98

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Harmonic errors of a 9.4 T all-REBCO NMR magnet affected by screening current and geometric inconsistency of coated conductors

Hongmin Yang, SangGap Lee, Hankil Yeom, Sehwan In et al.
3 citations
Scientific Reports
NMR spectroscopy and applications
1.98
article

Harmonic errors of a 9.4 T all-REBCO NMR magnet affected by screening current and geometric inconsistency of coated conductors

Hongmin Yang, SangGap Lee, Hankil Yeom, Sehwan In, Young Jin Hwang, Myunghwan Ku, Min Cheol Ahn, Jung Tae Lee, Seungyong Hahn, Jeseok Bang, Kwangmin Kim, Jaemin Kim, Youngil Kim, Hunju Lee, Yong-Ju Hong, Jae Young Jang
article en
3 citations

Abstract

REBa <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mmultiscripts><mml:mrow></mml:mrow> <mml:mn>2</mml:mn> <mml:mrow></mml:mrow></mml:mmultiscripts> </mml:math> Cu <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mmultiscripts><mml:mrow></mml:mrow> <mml:mn>3</mml:mn> <mml:mrow></mml:mrow></mml:mmultiscripts> </mml:math> O <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mmultiscripts><mml:mrow></mml:mrow> <mml:mrow><mml:mn>7</mml:mn> <mml:mo>-</mml:mo> <mml:mtext>x</mml:mtext></mml:mrow> <mml:mrow></mml:mrow></mml:mmultiscripts> </mml:math> (REBCO, RE = rare earth)-coated conductor is a competitive option in terms of current-carrying capacity and high-stress durability in developing high-field magnets for nuclear magnetic resonance (NMR) research. Meanwhile, a technical challenge in utilizing a stand-alone REBCO NMR magnet is an unexpected difference in the field uniformity between the designed and measured values after being constructed and charged, i.e., harmonic errors. Bortot et al., and Li et al., reported analytic evidence of the related issue. However, sufficient research has not yet been conducted, so evidence should be supplemented further. Here we report harmonic errors due to screening current and inconsistent conductor thickness, confirmed by a 400 MHz <sup>1</sup>H NMR magnet development project. The magnet was first charged up to its operating current, and then multiple overcharge-discharge cycles were applied, which was an empirically optimized operation protocol. A field mapping device obtained magnetic fields at designated locations in the room-temperature bore. The result showed over 100 ppm field uniformity difference between designed and measured values. A simulation model was developed considering screening current and inconsistent conductor thickness for reproducing the field distribution. Comparison of voltages and fields between simulation and measurement validated the model. Further analysis of the overcharge-discharge effect on harmonic errors demonstrated that even and odd-order harmonics are mainly attributed to screening current and geometric inconsistency while confirming the limitation of the screening current mitigation effect. Hence, we concluded that the desirable requirement of the sub-ppm level field uniformity generation might be barely possible with the current REBCO NMR magnet design approach.

Scientific ReportsVol. 14(1)
Kunsan National University (KR), Seoul National University (KR), Korea Maritime and Ocean University (KR), Korea University of Technology and Education (KR), Korea Institute of Machinery & Materials (KR), National University College (PR), National High Magnetic Field Laboratory (US), Korea Basic Science Institute (KR)
National Research Foundation, Seoul National University, Korea Basic Science Institute, National Research Foundation of Korea, Ministry of Science and ICT, South Korea
Affordable and clean energy
Openalex Percentile: Top 9%
NMR spectroscopy and applications
1.98
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.