In vivo optimization of the experimental conditions for the non-invasive optical assessment of breast density

In this study, time domain diffuse optical spectroscopy is performed in the range 600-1100 nm on 11 healthy volunteers with a portable system for the quantitative characterization of breast tissue in terms of optical properties and optically-derived blood parameters, tissue constituent concentrations, and scattering parameters. A measurement protocol involving different geometries (reflectance and transmittance), subject's positions (sitting and lying down), probing locations (outer, lower, and inner breast quadrants), and source-detector distances (2 and 3 cm) allowed us to investigate the effect of tissue heterogeneity and different measurement configurations on the results with the aim of identifying the best experimental conditions for the estimate of breast density (i.e., amount of fibro-glandular tissue in the breast) as a strong independent risk factor for breast cancer. Transmittance results, that in previous studies correlated strongly with mammographic density, are used as a reference for the initial test of the simpler and more comfortable reflectance measurement configuration. The higher source-detector distance, which probes deeper tissue, retrieves optical outcomes in agreement with higher average density tissue. Similarly, results on the outer quadrants indicate higher density than internal quadrants. These findings are coherent with breast anatomy since the concentration of dense fibro-glandular stroma is higher in deep tissue and towards the external portion of the breast, where the mammary gland is located. The dataset generated with this laboratory campaign is used to device an optimal measurement protocol for a future clinical trial, where optical results will be correlated with conventional mammographic density, allowing us to identify a subset of wavelengths and measurement configurations for an effective estimate of breast density. The final objective is the design of a simplified, compact and cost-effective optical device for a non-invasive, routine assessment of density-associated breast cancer risk.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2024-08-19
DOI
https://doi.org/10.1038/s41598-024-70099-x
Citations
6
Primary Topic
Optical Imaging and Spectroscopy Techniques
Type
article
Field-Weighted Citation Impact
2.43

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In vivo optimization of the experimental conditions for the non-invasive optical assessment of breast density

Giulia Maffeis, Rinaldo Cubeddu, Antonio Pifferi, Vamshi Damagatla et al.
6 citations
Scientific Reports
Optical Imaging and Spectroscopy Techniques
2.43
article

In vivo optimization of the experimental conditions for the non-invasive optical assessment of breast density

Giulia Maffeis, Rinaldo Cubeddu, Antonio Pifferi, Vamshi Damagatla, Paola Taroni, Nicola Serra
article en
6 citations

Abstract

In this study, time domain diffuse optical spectroscopy is performed in the range 600-1100 nm on 11 healthy volunteers with a portable system for the quantitative characterization of breast tissue in terms of optical properties and optically-derived blood parameters, tissue constituent concentrations, and scattering parameters. A measurement protocol involving different geometries (reflectance and transmittance), subject's positions (sitting and lying down), probing locations (outer, lower, and inner breast quadrants), and source-detector distances (2 and 3 cm) allowed us to investigate the effect of tissue heterogeneity and different measurement configurations on the results with the aim of identifying the best experimental conditions for the estimate of breast density (i.e., amount of fibro-glandular tissue in the breast) as a strong independent risk factor for breast cancer. Transmittance results, that in previous studies correlated strongly with mammographic density, are used as a reference for the initial test of the simpler and more comfortable reflectance measurement configuration. The higher source-detector distance, which probes deeper tissue, retrieves optical outcomes in agreement with higher average density tissue. Similarly, results on the outer quadrants indicate higher density than internal quadrants. These findings are coherent with breast anatomy since the concentration of dense fibro-glandular stroma is higher in deep tissue and towards the external portion of the breast, where the mammary gland is located. The dataset generated with this laboratory campaign is used to device an optimal measurement protocol for a future clinical trial, where optical results will be correlated with conventional mammographic density, allowing us to identify a subset of wavelengths and measurement configurations for an effective estimate of breast density. The final objective is the design of a simplified, compact and cost-effective optical device for a non-invasive, routine assessment of density-associated breast cancer risk.

Scientific ReportsVol. 14(1)
Istituto di Fotonica e Nanotecnologie (IT), Politecnico di Milano (IT)
European Commission
Good health and well-being
Openalex Percentile: Top 11%
Optical Imaging and Spectroscopy Techniques
2.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.