Paradoxical response during Para‐Hisian pacing in a case with fasciculo‐ventricular pathway: What is the mechanism?
Causes of paradoxical response include Pure His capture and inadvertent intermittent direct atrial capture. In the index case , we postulate that the likely mechanism of paradoxical prolongation could be due to decrement in the AV node due to the shortening of HH interval which happened as a result of a narrower H + Vc beat <i>following a wider Vc beat during decremetal pacing output</i>.