Axial Flow Fan Performance in a Forced Draught Air-Cooled Heat Exchanger for a Supercritical Carbon Dioxide Brayton Cycle

Abstract An axial flow cooling fan has been designed for use in a concentrated solar power plant. The plant is based on a supercritical carbon dioxide (sCO2) Brayton cycle, and uses a forced draft air-cooled heat exchanger (ACHE) for cooling. The fan performance has been investigated using both computational fluid dynamics (CFD) and scaled fan tests. This paper presents a CFD model that integrates the fan with the heat exchanger. The objective is to establish a foundation for similar models and to contribute to the development of efficient ACHE units designed for sCO2 power cycles. The finned-tube bundle is simplified, with a Porous Media Model representing the pressure drop through the bundle. Pressure inlet and -outlet boundary conditions are used, meaning the air flowrate is solved based on the fan and tube bundle interaction. The flowrate predicted by the CFD model is 0.5% higher than the analytical prediction, and 3.6% lower than the design value, demonstrating that the assumptions used in the design procedure are reasonable. The plenum height is also found to affect the flowrate, with shorter plenums resulting in higher flow rates and fan efficiencies, and longer plenums resulting in more uniform cooling air flow.

Authors

Institutions

Publication Details

Journal
Journal of Engineering for Gas Turbines and Power
Published
2024-08-19
DOI
https://doi.org/10.1115/1.4066248
Primary Topic
Heat transfer and supercritical fluids
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Axial Flow Fan Performance in a Forced Draught Air-Cooled Heat Exchanger for a Supercritical Carbon Dioxide Brayton Cycle

Sybrand Johannes van der Spuy, Francois D. Boshoff, Johannes Pretorius
Journal of Engineering for Gas Turbines and Power
Heat transfer and supercritical fluids
article

Axial Flow Fan Performance in a Forced Draught Air-Cooled Heat Exchanger for a Supercritical Carbon Dioxide Brayton Cycle

Sybrand Johannes van der Spuy, Francois D. Boshoff, Johannes Pretorius
article en

Abstract

Abstract An axial flow cooling fan has been designed for use in a concentrated solar power plant. The plant is based on a supercritical carbon dioxide (sCO2) Brayton cycle, and uses a forced draft air-cooled heat exchanger (ACHE) for cooling. The fan performance has been investigated using both computational fluid dynamics (CFD) and scaled fan tests. This paper presents a CFD model that integrates the fan with the heat exchanger. The objective is to establish a foundation for similar models and to contribute to the development of efficient ACHE units designed for sCO2 power cycles. The finned-tube bundle is simplified, with a Porous Media Model representing the pressure drop through the bundle. Pressure inlet and -outlet boundary conditions are used, meaning the air flowrate is solved based on the fan and tube bundle interaction. The flowrate predicted by the CFD model is 0.5% higher than the analytical prediction, and 3.6% lower than the design value, demonstrating that the assumptions used in the design procedure are reasonable. The plenum height is also found to affect the flowrate, with shorter plenums resulting in higher flow rates and fan efficiencies, and longer plenums resulting in more uniform cooling air flow.

Journal of Engineering for Gas Turbines and PowerVol. 147(1)
Stellenbosch University (ZA)
Affordable and clean energy
Openalex Percentile: Top 86%
Heat transfer and supercritical fluids
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Axial Flow Fan Performance in a Forced Draught Air-Cooled Heat Exchanger for a Supercritical Carbon Dioxide Brayton Cycle — Sybrand Johannes van der Spuy, Francois D. Boshoff, et al. · Journal of Engineering for Gas Turbines and Power (2024) | TGRS Research Map | TGRS