Electron cyclotron emission calibration with Thomson scattering using a wide scan of toroidal magnetic field of KSTAR

The Korea Superconducting Tokamak Advanced Research (KSTAR) tokamak is capable of operating at a wide range of toroidal magnetic fields up to 3.5 T at the major radius. The electron cyclotron emission (ECE) diagnostic on KSTAR is required to cover a broad frequency range for electron temperature profile measurements in both the low and high field sides. To meet these broadband requirements, the ECE system consists of W-band (78-110 GHz) and D-band (110-162 GHz) heterodyne radiometers. The two radiometers are connected to 28 and 48 detection channels, respectively. However, since the absolute ECE calibration based on the hot-cold calibration has been very challenging, an alternative method of calibration was performed using Thomson scattering measurements and varying toroidal magnetic fields. As the toroidal magnetic field is scanned from 1.6 to 3.2 T in steps of 0.2 T, most of the 76 ECE channels are calibrated relatively by the electron temperature values of Thomson scattering in a narrow region (0.2 < r/a <0.6). In this article, the methodological details of the ECE calibration are described. In addition, to demonstrate the robustness of the ECE calibration factors, the calibrated electron temperature profiles from ECE measurements are compared with the ion temperature profiles in terms of the plasma position as the plasma positon shifts outward.

Authors

Institutions

Publication Details

Journal
Review of Scientific Instruments
Published
2024-08-01
DOI
https://doi.org/10.1063/5.0218522
Citations
1
Primary Topic
Magnetic confinement fusion research
Type
article
Field-Weighted Citation Impact
0.66

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electron cyclotron emission calibration with Thomson scattering using a wide scan of toroidal magnetic field of KSTAR

Y.U. Nam, Kyu-Dong Lee, Seongmin Pyo, Jongha Lee
1 citations
Review of Scientific Instruments
Magnetic confinement fusion research
0.66
article

Electron cyclotron emission calibration with Thomson scattering using a wide scan of toroidal magnetic field of KSTAR

Y.U. Nam, Kyu-Dong Lee, Seongmin Pyo, Jongha Lee
article en
1 citations

Abstract

The Korea Superconducting Tokamak Advanced Research (KSTAR) tokamak is capable of operating at a wide range of toroidal magnetic fields up to 3.5 T at the major radius. The electron cyclotron emission (ECE) diagnostic on KSTAR is required to cover a broad frequency range for electron temperature profile measurements in both the low and high field sides. To meet these broadband requirements, the ECE system consists of W-band (78-110 GHz) and D-band (110-162 GHz) heterodyne radiometers. The two radiometers are connected to 28 and 48 detection channels, respectively. However, since the absolute ECE calibration based on the hot-cold calibration has been very challenging, an alternative method of calibration was performed using Thomson scattering measurements and varying toroidal magnetic fields. As the toroidal magnetic field is scanned from 1.6 to 3.2 T in steps of 0.2 T, most of the 76 ECE channels are calibrated relatively by the electron temperature values of Thomson scattering in a narrow region (0.2 < r/a <0.6). In this article, the methodological details of the ECE calibration are described. In addition, to demonstrate the robustness of the ECE calibration factors, the calibrated electron temperature profiles from ECE measurements are compared with the ion temperature profiles in terms of the plasma position as the plasma positon shifts outward.

Review of Scientific InstrumentsVol. 95(8)
Hanbat National University (KR), Korea Institute of Fusion Energy (KR)
Ministry of Science and ICT, South Korea
Affordable and clean energy
Openalex Percentile: Top 15%
Magnetic confinement fusion research
0.66
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Electron cyclotron emission calibration with Thomson scattering using a wide scan of toroidal magnetic field of KSTAR — Y.U. Nam, Kyu-Dong Lee, et al. · Review of Scientific Instruments (2024) | TGRS Research Map | TGRS