Numerical investigations of seismic-resilient techniques for legged fluid storage tanks utilising magnetorheological dampers

Different energy-dissipating devices have been proposed in the literature to attenuate the destructive effects of base excitations over fluid storage tanks. These structures have numerous applications in strategic industries and their failure can result in environmental hazards and huge economic losses. Proposed techniques in the literature for seismic energy dissipation of fluid-contained tanks are mostly centred on passive and active control mechanisms. Semi-active control devices using materials with adjustable properties offer advantages of both active and passive systems while removing their drawbacks. In this paper, the performance of a Magnetorheological (MR) damper on the seismic response reduction of fluid storage tanks through the application of three different control strategies including H2/LQG, PID, FOPID, and two passive techniques, i.e. Passive On, and Passive Off has been investigated. Parameters of the semi-active controllers are optimally designed for each aspect ratio and the applied ground motion using the Hunger Game Search (HGS) technique and finally, the semi-active Clipping algorithm commands the voltage to the damper. The fluid-tank-MR damper system has been examined under three Far-Fault and three Near-Fault ground motions. Numerical simulations have demonstrated that depending on the aspect ratio, applied ground motion, and the control strategy, the MR damper can mitigate the peak relative displacements and absolute accelerations of the two major modes of the system, i.e the rigid and impulsive modes, up to 72% and 67%, respectively. This proves the efficacy of these dampers in reducing the maximum base shear and overturning moment, hence mitigating the damage risks in these structures.

Authors

Institutions

Publication Details

Journal
Structures
Published
2024-08-19
DOI
https://doi.org/10.1016/j.istruc.2024.107090
Citations
3
Primary Topic
Vibration Control and Rheological Fluids
Type
article
Field-Weighted Citation Impact
0.78

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical investigations of seismic-resilient techniques for legged fluid storage tanks utilising magnetorheological dampers

Seyed Ehsan Aghakouchaki Hosseini, Sherif Beskhyroun
3 citations
Structures
Vibration Control and Rheological Fluids
0.78
article

Numerical investigations of seismic-resilient techniques for legged fluid storage tanks utilising magnetorheological dampers

Seyed Ehsan Aghakouchaki Hosseini, Sherif Beskhyroun
article en
3 citations

Abstract

Different energy-dissipating devices have been proposed in the literature to attenuate the destructive effects of base excitations over fluid storage tanks. These structures have numerous applications in strategic industries and their failure can result in environmental hazards and huge economic losses. Proposed techniques in the literature for seismic energy dissipation of fluid-contained tanks are mostly centred on passive and active control mechanisms. Semi-active control devices using materials with adjustable properties offer advantages of both active and passive systems while removing their drawbacks. In this paper, the performance of a Magnetorheological (MR) damper on the seismic response reduction of fluid storage tanks through the application of three different control strategies including H2/LQG, PID, FOPID, and two passive techniques, i.e. Passive On, and Passive Off has been investigated. Parameters of the semi-active controllers are optimally designed for each aspect ratio and the applied ground motion using the Hunger Game Search (HGS) technique and finally, the semi-active Clipping algorithm commands the voltage to the damper. The fluid-tank-MR damper system has been examined under three Far-Fault and three Near-Fault ground motions. Numerical simulations have demonstrated that depending on the aspect ratio, applied ground motion, and the control strategy, the MR damper can mitigate the peak relative displacements and absolute accelerations of the two major modes of the system, i.e the rigid and impulsive modes, up to 72% and 67%, respectively. This proves the efficacy of these dampers in reducing the maximum base shear and overturning moment, hence mitigating the damage risks in these structures.

StructuresVol. 68
Auckland University of Technology (NZ)
Auckland University of Technology, New Zealand, Earthquake Commission
Openalex Percentile: Top 31%
Vibration Control and Rheological Fluids
0.78
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.