Towards assessing reliability of next‐generation Internet of Things dashboard for anxiety risk classification

Abstract The ubiquitous Internet of Things (IoT) and sensing technologies provide an interesting opportunity of remote health monitoring and disease risk categorisation of populations. An end‐to‐end architecture is proposed to facilitate real‐time digital dashboards to visualise general anxiety risks of patients, especially during a pandemic, such as COVID‐19. To collect physiological data related to anxiety (heart rate, blood pressure, and saturation of peripheral oxygen [SPO 2 ]) and communicate them to a centralised dashboard, dubbed ‘X‐DASH’, a hardware prototype of the proposed architecture was developed using Node‐MCU and diverse sensors. The dashboard presents a smart categorisation of users' data, assessing their anxiety risks, to provide medical professionals and state authorities a clear visualisation of health risks in populations belonging to different regions. We categorised the risk levels as Normal, Mild, Moderate, Elevated, Severe, and Extreme, based on the collected physiological data and pre‐defined threshold values. The developed hardware prototype in this work was used to collect data from about 500 patients present at cardiac clinic of a leading general hospital in Karachi (Pakistan) and the anxiety risk levels were assigned based on pre‐defined threshold values. To validate the reliability of the X‐DASH, the personal physician of each patient was consulted and was requested to identify each of their anxiety risk levels. It was found that the risk levels suggested by X‐DASH, (based on data of heart rate, blood pressure, and SPO 2 were more than 90% accurate when compared with diagnoses of physicians. Subsequently, packet loss, delay and network overhead for the platform was compared when using MQTT, CoAP and Modbus. Although MQTT has shown higher delays, but it is still recommended due to having a higher reliability.

Authors

Institutions

Publication Details

Journal
IET Wireless Sensor Systems
Published
2024-08-19
DOI
https://doi.org/10.1049/wss2.12090
Citations
1
Primary Topic
Digital Mental Health Interventions
Type
article
Field-Weighted Citation Impact
0.41

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Towards assessing reliability of next‐generation Internet of Things dashboard for anxiety risk classification

Anwar Ahmed Khan, Shama Siddiqui, Indrakshi Dey, Farid Naït‐Abdesselam et al.
1 citations
IET Wireless Sensor Systems
Digital Mental Health Interventions
0.41
article

Towards assessing reliability of next‐generation Internet of Things dashboard for anxiety risk classification

Anwar Ahmed Khan, Shama Siddiqui, Indrakshi Dey, Farid Naït‐Abdesselam, Shamsul Arfeen Qasmi, Adnan Akhundzada
article en
1 citations

Abstract

Abstract The ubiquitous Internet of Things (IoT) and sensing technologies provide an interesting opportunity of remote health monitoring and disease risk categorisation of populations. An end‐to‐end architecture is proposed to facilitate real‐time digital dashboards to visualise general anxiety risks of patients, especially during a pandemic, such as COVID‐19. To collect physiological data related to anxiety (heart rate, blood pressure, and saturation of peripheral oxygen [SPO 2 ]) and communicate them to a centralised dashboard, dubbed ‘X‐DASH’, a hardware prototype of the proposed architecture was developed using Node‐MCU and diverse sensors. The dashboard presents a smart categorisation of users' data, assessing their anxiety risks, to provide medical professionals and state authorities a clear visualisation of health risks in populations belonging to different regions. We categorised the risk levels as Normal, Mild, Moderate, Elevated, Severe, and Extreme, based on the collected physiological data and pre‐defined threshold values. The developed hardware prototype in this work was used to collect data from about 500 patients present at cardiac clinic of a leading general hospital in Karachi (Pakistan) and the anxiety risk levels were assigned based on pre‐defined threshold values. To validate the reliability of the X‐DASH, the personal physician of each patient was consulted and was requested to identify each of their anxiety risk levels. It was found that the risk levels suggested by X‐DASH, (based on data of heart rate, blood pressure, and SPO 2 were more than 90% accurate when compared with diagnoses of physicians. Subsequently, packet loss, delay and network overhead for the platform was compared when using MQTT, CoAP and Modbus. Although MQTT has shown higher delays, but it is still recommended due to having a higher reliability.

IET Wireless Sensor SystemsVol. 14(6)
Bahawal Victoria Hospital (PK), DHA Suffa University (PK), Qatar Science and Technology Park (QA), ILMA University (PK), Walton Institute for Information and Communications Systems Science, Waterford Institute of Technology (IE), University of Missouri (US)
Irish Research eLibrary
Good health and well-being
Openalex Percentile: Top 35%
Digital Mental Health Interventions
0.41
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.