Precursor‐Derived Sensing Interdigitated Electrode Microstructures Based on Platinum and Nano Porous Carbon

Interdigital electrodes were prepared using nanoimprint lithography and piezoelectric inkjet printing. These processes are simpler and more cost-effective than the industrially used electron beam lithography because of their purely mechanical process step. For the investigation of material dependence, platinum as well as carbon electrodes were fabricated. Afterwards electrodes with various line widths and spacings were tested for the application as a chemiresistive sensor for ferrocenyl-methanol and the influence of the gap-width and conductor cross-section on the sensitivity was investigated. The general suitability of the systems for the production of such structures could be confirmed. Structures with a limit of detection (LOD) down to 1.2 μM and 35.9 μM could be produced for carbon and platinum, respectively, as well as a response time of 3.6 s was achieved.

Authors

Institutions

Publication Details

Journal
ChemistryOpen
Published
2024-08-19
DOI
https://doi.org/10.1002/open.202400179
Citations
5
Primary Topic
Neuroscience and Neural Engineering
Type
article
Field-Weighted Citation Impact
1.34
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Precursor‐Derived Sensing Interdigitated Electrode Microstructures Based on Platinum and Nano Porous Carbon

Lydia Galle, Stefan Kaskel, Julia Grothe, Lukas Mielewczyk et al.
5 citations
ChemistryOpen
Neuroscience and Neural Engineering
1.34
article

Precursor‐Derived Sensing Interdigitated Electrode Microstructures Based on Platinum and Nano Porous Carbon

Lydia Galle, Stefan Kaskel, Julia Grothe, Lukas Mielewczyk, Nick Niese
article en
5 citations

Abstract

Interdigital electrodes were prepared using nanoimprint lithography and piezoelectric inkjet printing. These processes are simpler and more cost-effective than the industrially used electron beam lithography because of their purely mechanical process step. For the investigation of material dependence, platinum as well as carbon electrodes were fabricated. Afterwards electrodes with various line widths and spacings were tested for the application as a chemiresistive sensor for ferrocenyl-methanol and the influence of the gap-width and conductor cross-section on the sensitivity was investigated. The general suitability of the systems for the production of such structures could be confirmed. Structures with a limit of detection (LOD) down to 1.2 μM and 35.9 μM could be produced for carbon and platinum, respectively, as well as a response time of 3.6 s was achieved.

ChemistryOpenVol. 13(11)
Technische Universität Dresden (DE)
Openalex Percentile: Top 20%
Neuroscience and Neural Engineering
1.34
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Precursor‐Derived Sensing Interdigitated Electrode Microstructures Based on Platinum and Nano Porous Carbon — Lydia Galle, Stefan Kaskel, et al. · ChemistryOpen (2024) | TGRS Research Map | TGRS