Digital Ion Trap Isolation and Mass Analysis of Macromolecular Analytes with Multiply Charged Ion Attachment

Multiply charged ions produced by electrospray ionization (ESI) of heterogeneous mixtures of macromolecular analytes under native conditions are typically confined to relatively narrow ranges of mass-to-charge (<i>m</i>/<i>z</i>) ratio, often with extensive overlap. This scenario makes charge and mass assignments extremely challenging, particularly when individual charge states are unresolved. An ion/ion reaction strategy involving multiply charged ion attachment (MIA) to the mixture components in a narrow range of <i>m</i>/<i>z</i> can facilitate charge and mass assignment. In MIA operation, multiply charged reagent ions are attached to the analyte ions of opposite polarity to provide large <i>m</i>/<i>z</i> displacements resulting from both large changes in mass and charge. However, charge reduction of the high <i>m</i>/<i>z</i> ions initially generated under native ESI conditions requires the ability to isolate high <i>m</i>/<i>z</i> ions and to analyze even higher <i>m</i>/<i>z</i> product ions. Digital ion trap (DIT) operation offers means for both high <i>m</i>/<i>z</i> ion isolation and high <i>m</i>/<i>z</i> mass analysis, in addition to providing conditions for the reaction of oppositely charged ions. The feasibility of conducting MIA experiments in a DIT that takes advantage of high <i>m</i>/<i>z</i> ion operation is demonstrated here using a tandem 2D-3D DIT instrument. Proof-of-concept MIA experiments with cations derived from β-galactosidase using the 20- charge state of human serum immunoglobulin G (IgG, ∼149 kDa) as the reagent anion are described. MIA experiments involving mixtures of ions derived from the <i>E. coli.</i> ribosome are also described. For example, three components in a mixture of 70S particles (>2.2 MDa) were resolved and assigned with masses and charges following an MIA experiment involving the 20- charge state of human serum IgG.

Authors

Institutions

Publication Details

Journal
Journal of the American Society for Mass Spectrometry
Published
2024-08-19
DOI
https://doi.org/10.1021/jasms.4c00292
Citations
3
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.72

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Digital Ion Trap Isolation and Mass Analysis of Macromolecular Analytes with Multiply Charged Ion Attachment

Nicolas J. Pizzala, Scott A. McLuckey, Erick G. Báez Bolívar, Nicholas R. Ellin et al.
3 citations
Journal of the American Society for Mass Spectrometry
Mass Spectrometry Techniques and Applications
0.72
article

Digital Ion Trap Isolation and Mass Analysis of Macromolecular Analytes with Multiply Charged Ion Attachment

Nicolas J. Pizzala, Scott A. McLuckey, Erick G. Báez Bolívar, Nicholas R. Ellin, Liangxuan Fu
article en
3 citations

Abstract

Multiply charged ions produced by electrospray ionization (ESI) of heterogeneous mixtures of macromolecular analytes under native conditions are typically confined to relatively narrow ranges of mass-to-charge (<i>m</i>/<i>z</i>) ratio, often with extensive overlap. This scenario makes charge and mass assignments extremely challenging, particularly when individual charge states are unresolved. An ion/ion reaction strategy involving multiply charged ion attachment (MIA) to the mixture components in a narrow range of <i>m</i>/<i>z</i> can facilitate charge and mass assignment. In MIA operation, multiply charged reagent ions are attached to the analyte ions of opposite polarity to provide large <i>m</i>/<i>z</i> displacements resulting from both large changes in mass and charge. However, charge reduction of the high <i>m</i>/<i>z</i> ions initially generated under native ESI conditions requires the ability to isolate high <i>m</i>/<i>z</i> ions and to analyze even higher <i>m</i>/<i>z</i> product ions. Digital ion trap (DIT) operation offers means for both high <i>m</i>/<i>z</i> ion isolation and high <i>m</i>/<i>z</i> mass analysis, in addition to providing conditions for the reaction of oppositely charged ions. The feasibility of conducting MIA experiments in a DIT that takes advantage of high <i>m</i>/<i>z</i> ion operation is demonstrated here using a tandem 2D-3D DIT instrument. Proof-of-concept MIA experiments with cations derived from β-galactosidase using the 20- charge state of human serum immunoglobulin G (IgG, ∼149 kDa) as the reagent anion are described. MIA experiments involving mixtures of ions derived from the <i>E. coli.</i> ribosome are also described. For example, three components in a mixture of 70S particles (>2.2 MDa) were resolved and assigned with masses and charges following an MIA experiment involving the 20- charge state of human serum IgG.

Journal of the American Society for Mass SpectrometryVol. 35(9)
Purdue University West Lafayette (US)
National Institute of General Medical Sciences
Openalex Percentile: Top 34%
Mass Spectrometry Techniques and Applications
0.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.