Computed tomography of the palatal anatomy with micrometer resolution

Palatoplasty in infants with cleft palate aims to reconstruct the intricate three-dimensional anatomy and restore the velopharyngeal function, which is essential for swallowing, speech, and ventilation of the middle ear through the opening of the Eustachian tube. The non-destructive analysis of the microarchitecture around the pterygoid hamulus using hard x-rays should enhance the existing knowledge from dissection and histological studies. Specifically, the micro-anatomical relationship between the palatine aponeurosis, the tendon of the tensor veli palatini muscle, and the pterygoid hamulus must be characterized to understand their structural relationship and functional implications. At the cellular level, the arrangement of fibers within muscle fascicles needs to be clarified. The right half of a historical plastinated infant cadaveric head was examined with two laboratory-based micro computed tomography (μCT) systems: phoenix|xray nanotom<sup>®</sup> m for imaging of the entire specimen with a pixel size of 55μm; and Zeiss Xradia 610 Versa for local tomography with a pixel size of 3.4μm. Using synchrotron radiation-based microtomography, additional measurements were performed with a pixel size of 3.24μm. The resulting images were rigidly registered and analyzed. Automated threshold-based segmentation of bones and manual segmentation of muscles, tendons, and aponeurosis, were performed to visualize their topographic relationships in three dimensions. An unstained segment of a human gracilis muscle was examined using the Exciscope Polaris with a pixel size of 0.35μm, and the fiber architecture was visually inspected. Laboratory-based x-ray μCT systems are suitable for virtual-histology examination of soft tissues and visualization of subcellular structures therein. Synchrotron radiation-based μCT with phase retrieval provided additional contrast within the plastinated soft tissues. The findings of this study support the hypothesis that the palatal muscles form a complex muscle sling around the pterygoid hamulus, underscoring the importance of preserving this bony protuberance during cleft palate repair.

Authors

Institutions

Publication Details

Published
2024-08-19
DOI
https://doi.org/10.1117/12.3035601
Primary Topic
Dental Radiography and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Computed tomography of the palatal anatomy with micrometer resolution

Robert Atwood, Szilvia E. Mezey, Magdalena Müller‐Gerbl, Daphne Schönegg et al.
Dental Radiography and Imaging
article

Computed tomography of the palatal anatomy with micrometer resolution

Robert Atwood, Szilvia E. Mezey, Magdalena Müller‐Gerbl, Daphne Schönegg, Christine Tanner, G. V. Schulz, Hans Deyhle, Bert Müller, A. Müller, Sharif Ahmed
article en

Abstract

Palatoplasty in infants with cleft palate aims to reconstruct the intricate three-dimensional anatomy and restore the velopharyngeal function, which is essential for swallowing, speech, and ventilation of the middle ear through the opening of the Eustachian tube. The non-destructive analysis of the microarchitecture around the pterygoid hamulus using hard x-rays should enhance the existing knowledge from dissection and histological studies. Specifically, the micro-anatomical relationship between the palatine aponeurosis, the tendon of the tensor veli palatini muscle, and the pterygoid hamulus must be characterized to understand their structural relationship and functional implications. At the cellular level, the arrangement of fibers within muscle fascicles needs to be clarified. The right half of a historical plastinated infant cadaveric head was examined with two laboratory-based micro computed tomography (μCT) systems: phoenix|xray nanotom<sup>®</sup> m for imaging of the entire specimen with a pixel size of 55μm; and Zeiss Xradia 610 Versa for local tomography with a pixel size of 3.4μm. Using synchrotron radiation-based microtomography, additional measurements were performed with a pixel size of 3.24μm. The resulting images were rigidly registered and analyzed. Automated threshold-based segmentation of bones and manual segmentation of muscles, tendons, and aponeurosis, were performed to visualize their topographic relationships in three dimensions. An unstained segment of a human gracilis muscle was examined using the Exciscope Polaris with a pixel size of 0.35μm, and the fiber architecture was visually inspected. Laboratory-based x-ray μCT systems are suitable for virtual-histology examination of soft tissues and visualization of subcellular structures therein. Synchrotron radiation-based μCT with phase retrieval provided additional contrast within the plastinated soft tissues. The findings of this study support the hypothesis that the palatal muscles form a complex muscle sling around the pterygoid hamulus, underscoring the importance of preserving this bony protuberance during cleft palate repair.

University of Basel (CH), University Hospital of Bern (CH), Diamond Light Source (GB)
Openalex Percentile: Top 80%
Dental Radiography and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.