Virtual flow diverter deployment and embedding for hemodynamic simulations

Flow-diverter stents offer clinicians an effective solution for treating intracranial aneurysms, especially in cases where other devices may be unsuitable. However, strongly deviating success rates among different centres, manufacturers, and aneurysm phenotypes highlight the need for better in-situ studies of these devices. To support research in this area, virtual stenting algorithms have been proposed that, combined with computational fluid dynamics, provide insights into the hemodynamic alterations induced by the device. Yet, many existing algorithms rely on uncertain parameters, such as the forces applied during operation, fail to predict the length of the device after deployment, or lack robust validation steps, raising concerns about their reliability. Therefore, we developed a robust deployment technique that builds upon the geometrical features of the vessel and includes advancements from previous works. The algorithm is detailed and validated against literature examples, in-vitro experiments, and patient data, achieving a mean angular error below 5° in the latter. Furthermore, we describe and demonstrate how the deployed device can be embedded in a computational mesh using open-source tools and anisotropic meshing routines.

Authors

Institutions

Publication Details

Journal
Computers in Biology and Medicine
Published
2024-08-19
DOI
https://doi.org/10.1016/j.compbiomed.2024.109023
Citations
5
Primary Topic
Intracranial Aneurysms: Treatment and Complications
Type
article
Field-Weighted Citation Impact
1.85

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Virtual flow diverter deployment and embedding for hemodynamic simulations

Elie Hachem, Vincent Lannelongue, Aurèle Goetz, Pablo Jeken Rico et al.
5 citations
Computers in Biology and Medicine
Intracranial Aneurysms: Treatment and Complications
1.85
article

Virtual flow diverter deployment and embedding for hemodynamic simulations

Elie Hachem, Vincent Lannelongue, Aurèle Goetz, Pablo Jeken Rico, Jacques Sédat, Yves Chau
article en
5 citations

Abstract

Flow-diverter stents offer clinicians an effective solution for treating intracranial aneurysms, especially in cases where other devices may be unsuitable. However, strongly deviating success rates among different centres, manufacturers, and aneurysm phenotypes highlight the need for better in-situ studies of these devices. To support research in this area, virtual stenting algorithms have been proposed that, combined with computational fluid dynamics, provide insights into the hemodynamic alterations induced by the device. Yet, many existing algorithms rely on uncertain parameters, such as the forces applied during operation, fail to predict the length of the device after deployment, or lack robust validation steps, raising concerns about their reliability. Therefore, we developed a robust deployment technique that builds upon the geometrical features of the vessel and includes advancements from previous works. The algorithm is detailed and validated against literature examples, in-vitro experiments, and patient data, achieving a mean angular error below 5° in the latter. Furthermore, we describe and demonstrate how the deployed device can be embedded in a computational mesh using open-source tools and anisotropic meshing routines.

Computers in Biology and MedicineVol. 180
Centre National de la Recherche Scientifique (FR), Université Paris Sciences et Lettres (FR), Society of Interventional Radiology (US), École Nationale Supérieure des Mines de Paris (FR)
Université de Recherche Paris Sciences et Lettres, Horizon 2020 Framework Programme
Openalex Percentile: Top 14%
Intracranial Aneurysms: Treatment and Complications
1.85
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Virtual flow diverter deployment and embedding for hemodynamic simulations — Elie Hachem, Vincent Lannelongue, et al. · Computers in Biology and Medicine (2024) | TGRS Research Map | TGRS