Flexible Belt Constrained Catheterization Robot

Currently, vascular interventional technology is the most effective method for treating cardiovascular and cerebrovascular diseases. Research on vascular interventional robotic technology has become a popular topic. This article proposes a catheterization robot based on two flexible belts constraint, the flexible rod such as catheter, guidewire or balloon can not only be constrained by the flexible belts, but also achieve its purpose of being transported through the interaction force with the belts. Through setting comparative experiment, the results indicate that the proposed catheterization robot in this article meets the relevant usage requirements, and it can also realize the long-stroke transportation of the flexible rod, the delivery error is within 2.0 mm, and the rotation angle error is within 2.0°.

Authors

Institutions

Publication Details

Published
2024-08-04
DOI
https://doi.org/10.1109/icma61710.2024.10633087
Citations
1
Primary Topic
Soft Robotics and Applications
Type
article
Field-Weighted Citation Impact
0.18
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Flexible Belt Constrained Catheterization Robot

Peng Lin, Hao Liu, Jingyang Sun, Ming Liang et al.
1 citations
Soft Robotics and Applications
0.18
article

Flexible Belt Constrained Catheterization Robot

Peng Lin, Hao Liu, Jingyang Sun, Ming Liang, Cong Sun, Fangxing Tian, Jianan Hou
article en
1 citations

Abstract

Currently, vascular interventional technology is the most effective method for treating cardiovascular and cerebrovascular diseases. Research on vascular interventional robotic technology has become a popular topic. This article proposes a catheterization robot based on two flexible belts constraint, the flexible rod such as catheter, guidewire or balloon can not only be constrained by the flexible belts, but also achieve its purpose of being transported through the interaction force with the belts. Through setting comparative experiment, the results indicate that the proposed catheterization robot in this article meets the relevant usage requirements, and it can also realize the long-stroke transportation of the flexible rod, the delivery error is within 2.0 mm, and the rotation angle error is within 2.0°.

Shenyang Institute of Automation (CN), Chinese Academy of Sciences (CN), General Hospital of Shenyang Military Region (CN), Chinese People's Liberation Army (CN), Northeastern University (CN)
Affordable and clean energy
Openalex Percentile: Top 53%
Soft Robotics and Applications
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.