A Novel Vascular Interventional Robot for Cardiac Ablation Surgery

In recent years, force sensing and drive control at the distal end of ablation catheters have attracted widespread interest from scholars around the world. Among them, the challenge of high-precision operation of ablation catheters has attracted much attention. To address this problem, this study proposes a non-fixed modular ablation catheter clamping and pushing mechanism. The mechanism is based on a non-fixed modular design, aiming to avoid common under-clamping sliding errors in catheter operations, and achieves effective separation of the robot body and surgical instruments, allowing the ablation catheter to be quickly replaced and asynchronously sterilized. In addition, we conducted a modal analysis of the clamp-push structure, and the results showed that the modal frequency of the clamp-push structure is very low, so the catheter is not susceptible to the resonance effect of external excitation when it is pushed. This innovative design aims to further improve the accuracy, safety and intelligence of the vascular interventional surgical robot, providing reliable support for the success rate and safety of ablation surgery.

Authors

Institutions

Publication Details

Published
2024-08-04
DOI
https://doi.org/10.1109/icma61710.2024.10633106
Primary Topic
Cardiac Arrhythmias and Treatments
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Novel Vascular Interventional Robot for Cardiac Ablation Surgery

Tao Jiang, Linshuai Zhang, Yang Yang, Xinyu Zhang et al.
Cardiac Arrhythmias and Treatments
article

A Novel Vascular Interventional Robot for Cardiac Ablation Surgery

Tao Jiang, Linshuai Zhang, Yang Yang, Xinyu Zhang, Xinlin Hao, Jinshan Zuo
article en

Abstract

In recent years, force sensing and drive control at the distal end of ablation catheters have attracted widespread interest from scholars around the world. Among them, the challenge of high-precision operation of ablation catheters has attracted much attention. To address this problem, this study proposes a non-fixed modular ablation catheter clamping and pushing mechanism. The mechanism is based on a non-fixed modular design, aiming to avoid common under-clamping sliding errors in catheter operations, and achieves effective separation of the robot body and surgical instruments, allowing the ablation catheter to be quickly replaced and asynchronously sterilized. In addition, we conducted a modal analysis of the clamp-push structure, and the results showed that the modal frequency of the clamp-push structure is very low, so the catheter is not susceptible to the resonance effect of external excitation when it is pushed. This innovative design aims to further improve the accuracy, safety and intelligence of the vascular interventional surgical robot, providing reliable support for the success rate and safety of ablation surgery.

Chengdu University of Traditional Chinese Medicine (CN)
National Natural Science Foundation of China, Chengdu University
Openalex Percentile: Top 75%
Cardiac Arrhythmias and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Novel Vascular Interventional Robot for Cardiac Ablation Surgery — Tao Jiang, Linshuai Zhang, et al. · (2024) | TGRS Research Map | TGRS