Generating PET images from low-dose data using a cycle PET reconstruction convolutional neural network

A high-quality PET image usually requires the injection of a sufficient amount of radiotracer, which increases the risk of radiation exposure to the examinee and medical staff. Therefore, performing PET scanning with a reduced injection dose has broad application in clinical practice. However, low-dose PET data can cause problems in the reconstruction process, such as increased noise and degraded image quality. To address these issues, we adopt the idea of a back-projection filter (BPF) based on deep learning methods to reconstruct images. First, the raw data is back-projected (BP) to generate a low-dose BP (LDBP) image, as the PET sinogram is quite large. Second, a cycle PET reconstruction convolutional neural network (CPR-CNN) is introduced to realize a reconstruction process from a LDBP image to a deep learning-based full-dose PET (DL-FDPET) image. CPR-CNN employs two reconstruction models to separately learn bidirectional mappings between pairs of input images to enhance the image reconstruction performance. Our proposed CPR-CNN achieves comparable results in maintaining resolution and denoising of DL-FDPET images.

Authors

Institutions

Publication Details

Published
2024-08-04
DOI
https://doi.org/10.1109/icma61710.2024.10632916
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Generating PET images from low-dose data using a cycle PET reconstruction convolutional neural network

Hongwei Ye, Mingwei Zhai, Tingting Wu, Jianda Han et al.
Medical Imaging Techniques and Applications
article

Generating PET images from low-dose data using a cycle PET reconstruction convolutional neural network

Hongwei Ye, Mingwei Zhai, Tingting Wu, Jianda Han, Hongpeng Wang
article en

Abstract

A high-quality PET image usually requires the injection of a sufficient amount of radiotracer, which increases the risk of radiation exposure to the examinee and medical staff. Therefore, performing PET scanning with a reduced injection dose has broad application in clinical practice. However, low-dose PET data can cause problems in the reconstruction process, such as increased noise and degraded image quality. To address these issues, we adopt the idea of a back-projection filter (BPF) based on deep learning methods to reconstruct images. First, the raw data is back-projected (BP) to generate a low-dose BP (LDBP) image, as the PET sinogram is quite large. Second, a cycle PET reconstruction convolutional neural network (CPR-CNN) is introduced to realize a reconstruction process from a LDBP image to a deep learning-based full-dose PET (DL-FDPET) image. CPR-CNN employs two reconstruction models to separately learn bidirectional mappings between pairs of input images to enhance the image reconstruction performance. Our proposed CPR-CNN achieves comparable results in maintaining resolution and denoising of DL-FDPET images.

Nankai University (CN), Hangzhou Dianzi University (CN)
Openalex Percentile: Top 78%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.