Method for Enhancing Stability of Tension in Cable-Driven Minimally Invasive Surgical Instruments

This study proposes a method aimed at enhancing the stability of tension in cable-driven minimally invasive surgical instruments. Despite the widespread use of cable-driven instruments due to their lightweight and flexibility, those with hinge joints encounter a significant problem of cable loosening during transmission. This is attributed to the non-circular geometric characteristics of hinge joints, leading to a loss of cable tension during transmission and subsequently compromising the precision at the instrument's end. To tackle this issue, a design solution involving a cam is proposed in this study, aiming to provide a more suitable cable length for hinge joints to reduce cable tension loss. Through a series of analytical procedures and experiments, the method optimizes the mechanical design to mitigate tension fluctuations during surgical procedures. Experimental results demonstrate that adopting the design solution with a cam can improve the stability of cable tension in hinge joints by 71% within a motor rotation angle of 30 degrees. This method offers valuable insights into the development of more reliable surgical instruments for delicate procedures.

Authors

Institutions

Publication Details

Published
2024-08-04
DOI
https://doi.org/10.1109/icma61710.2024.10633097
Citations
2
Primary Topic
Anatomy and Medical Technology
Type
article
Field-Weighted Citation Impact
0.37
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Method for Enhancing Stability of Tension in Cable-Driven Minimally Invasive Surgical Instruments

Yue Yu, Chengcheng Cai, Xingchi Liu, Jinhua Li et al.
2 citations
Anatomy and Medical Technology
0.37
article

Method for Enhancing Stability of Tension in Cable-Driven Minimally Invasive Surgical Instruments

Yue Yu, Chengcheng Cai, Xingchi Liu, Jinhua Li, Jiang Xu, Jianchang Zhao
article en
2 citations

Abstract

This study proposes a method aimed at enhancing the stability of tension in cable-driven minimally invasive surgical instruments. Despite the widespread use of cable-driven instruments due to their lightweight and flexibility, those with hinge joints encounter a significant problem of cable loosening during transmission. This is attributed to the non-circular geometric characteristics of hinge joints, leading to a loss of cable tension during transmission and subsequently compromising the precision at the instrument's end. To tackle this issue, a design solution involving a cam is proposed in this study, aiming to provide a more suitable cable length for hinge joints to reduce cable tension loss. Through a series of analytical procedures and experiments, the method optimizes the mechanical design to mitigate tension fluctuations during surgical procedures. Experimental results demonstrate that adopting the design solution with a cam can improve the stability of cable tension in hinge joints by 71% within a motor rotation angle of 30 degrees. This method offers valuable insights into the development of more reliable surgical instruments for delicate procedures.

Tianjin University (CN)
Affordable and clean energy
Openalex Percentile: Top 44%
Anatomy and Medical Technology
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.