Path Planning of Breast Ultrasound Scanning Based on Three-Dimensional Point Cloud Model

The incidence rate of breast cancer is increasing year by year in the world. Traditional breast ultrasound scanning methods are increasingly unable to meet people's medical needs. To improve the efficiency and accuracy of breast ultrasound scanning, a method of breast ultrasound scanning path planning based on three-dimensional (3D) point cloud model is proposed. A method of 3D breast point cloud reconstruction based on kinect camera is adopted. Kinect camera was calibrated and breast images were collected. 3D breast point cloud model was established based on spatial point. A method of extracting path points in ultrasound scanning based on the minimum two-dimensional fitting plane is proposed, and the extracted path points are fitted by cubic B-spline curve. The experimental platform was built and the hand-to-eye calibration experiment was conducted. Through the path error experiment of ultrasound scanning, it is verified that the average error between the planned path and the actual path in x, y, and z direction is 0.66 mm, 0.68 mm and 0.82 mm.

Authors

Institutions

Publication Details

Published
2024-08-04
DOI
https://doi.org/10.1109/icma61710.2024.10633205
Primary Topic
Medical Imaging and Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Path Planning of Breast Ultrasound Scanning Based on Three-Dimensional Point Cloud Model

Yongde Zhang, Haiyan Du, Xinran Zhang, Dong Guo
Medical Imaging and Analysis
article

Path Planning of Breast Ultrasound Scanning Based on Three-Dimensional Point Cloud Model

Yongde Zhang, Haiyan Du, Xinran Zhang, Dong Guo
article en

Abstract

The incidence rate of breast cancer is increasing year by year in the world. Traditional breast ultrasound scanning methods are increasingly unable to meet people's medical needs. To improve the efficiency and accuracy of breast ultrasound scanning, a method of breast ultrasound scanning path planning based on three-dimensional (3D) point cloud model is proposed. A method of 3D breast point cloud reconstruction based on kinect camera is adopted. Kinect camera was calibrated and breast images were collected. 3D breast point cloud model was established based on spatial point. A method of extracting path points in ultrasound scanning based on the minimum two-dimensional fitting plane is proposed, and the extracted path points are fitted by cubic B-spline curve. The experimental platform was built and the hand-to-eye calibration experiment was conducted. Through the path error experiment of ultrasound scanning, it is verified that the average error between the planned path and the actual path in x, y, and z direction is 0.66 mm, 0.68 mm and 0.82 mm.

Harbin University of Science and Technology (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 88%
Medical Imaging and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.