Transient Synchronization Stability of Grid-Tied Multi-VSCs System Considering Nonlinear Damping and Transient Interactions

This article investigates the phase-locked loop (PLL) synchronization transient stability (PLL-STS) issue of grid-tied multiple voltage source converters (MVSCs) systems, specifically focusing on transient stability evaluation and transient interaction analysis. First, a novel PLL-STS assessment method for MVSCs systems has been proposed, which considers angular frequency jumps, nonlinear damping, and transient interactions among VSCs. Compared with previous studies, this method can accurately evaluate PLL-STS of MVSCs system since the acceleration and deceleration areas of VSCs can be accurately determined by combining equal-area criterion and numerical integration method. Moreover, it can identify the dominant converters which lead to transient instability. Second, by introducing static and dynamic interaction coefficients, influence of static and dynamic interaction on the transient stability of individual converters is quantitatively analyzed. Finally, the theoretical analysis results are verified by PSCAD/ EMTDC time-domain simulation results and RT-LAB hardware-in-the-loop experimental results.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Power Electronics
Published
2024-08-19
DOI
https://doi.org/10.1109/tpel.2024.3445352
Citations
13
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
4.27
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Transient Synchronization Stability of Grid-Tied Multi-VSCs System Considering Nonlinear Damping and Transient Interactions

Xu Zhou, Xialin Li, Li Guo, Jiebei Zhu et al.
13 citations
IEEE Transactions on Power Electronics
Microgrid Control and Optimization
4.27
article

Transient Synchronization Stability of Grid-Tied Multi-VSCs System Considering Nonlinear Damping and Transient Interactions

Xu Zhou, Xialin Li, Li Guo, Jiebei Zhu, Zhongguan Wang, Zhi Wang, Chengshan Wang
article en
13 citations

Abstract

This article investigates the phase-locked loop (PLL) synchronization transient stability (PLL-STS) issue of grid-tied multiple voltage source converters (MVSCs) systems, specifically focusing on transient stability evaluation and transient interaction analysis. First, a novel PLL-STS assessment method for MVSCs systems has been proposed, which considers angular frequency jumps, nonlinear damping, and transient interactions among VSCs. Compared with previous studies, this method can accurately evaluate PLL-STS of MVSCs system since the acceleration and deceleration areas of VSCs can be accurately determined by combining equal-area criterion and numerical integration method. Moreover, it can identify the dominant converters which lead to transient instability. Second, by introducing static and dynamic interaction coefficients, influence of static and dynamic interaction on the transient stability of individual converters is quantitatively analyzed. Finally, the theoretical analysis results are verified by PSCAD/ EMTDC time-domain simulation results and RT-LAB hardware-in-the-loop experimental results.

IEEE Transactions on Power ElectronicsVol. 39(12)
Tianjin University (CN)
Affordable and clean energy
Openalex Percentile: Top 5%
Microgrid Control and Optimization
4.27
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.