Cuffless Blood Pressure Estimation Model Based on Prior Information of Physiological Data and LSTM

Blood pressure (BP), as a key indicator, reflects the health status of the cardiovascular system. To address the issue of accurate BP measurement, a BP estimation model based on electrocardiogram (ECG) and photoplethysmography (PPG) and prior information on pulse transit time (PTT) has been proposed. This model features a parallel feature extraction module based on long short-term memory (LSTM) for extracting features and incorporates the prior information PTT through a pretraining strategy. The performance of the model is analyzed using the UCI cuffless BP estimation dataset (UCI-BP) along with correlation analysis, Bland–Altman analysis, and statistical histogram analysis of estimation error. The results show that the mean absolute error (MAE) and standard deviation (SD) for systolic BP (SBP) are 1.02 and 1.49 mmHg, respectively, and for diastolic BP (DBP) are 3.16 and 3.74 mmHg, respectively. These results meet the BP standards of the American Association for Medical Devices (AAMI) and the class A standard of the British Hypertension Society (BHS).

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2024-08-19
DOI
https://doi.org/10.1109/jsen.2024.3438773
Citations
3
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.55
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cuffless Blood Pressure Estimation Model Based on Prior Information of Physiological Data and LSTM

Peng Guo, Junjie Li, Yi Lu, Jiu Feng et al.
3 citations
IEEE Sensors Journal
Non-Invasive Vital Sign Monitoring
0.55
article

Cuffless Blood Pressure Estimation Model Based on Prior Information of Physiological Data and LSTM

Peng Guo, Junjie Li, Yi Lu, Jiu Feng, Yicun Liu, Yang Lv
article en
3 citations

Abstract

Blood pressure (BP), as a key indicator, reflects the health status of the cardiovascular system. To address the issue of accurate BP measurement, a BP estimation model based on electrocardiogram (ECG) and photoplethysmography (PPG) and prior information on pulse transit time (PTT) has been proposed. This model features a parallel feature extraction module based on long short-term memory (LSTM) for extracting features and incorporates the prior information PTT through a pretraining strategy. The performance of the model is analyzed using the UCI cuffless BP estimation dataset (UCI-BP) along with correlation analysis, Bland–Altman analysis, and statistical histogram analysis of estimation error. The results show that the mean absolute error (MAE) and standard deviation (SD) for systolic BP (SBP) are 1.02 and 1.49 mmHg, respectively, and for diastolic BP (DBP) are 3.16 and 3.74 mmHg, respectively. These results meet the BP standards of the American Association for Medical Devices (AAMI) and the class A standard of the British Hypertension Society (BHS).

IEEE Sensors JournalVol. 24(21)
Beijing Institute of Technology (CN), Shijiazhuang University (CN), Lanzhou University (CN), Xi'an Jiaotong University (CN)
Openalex Percentile: Top 38%
Non-Invasive Vital Sign Monitoring
0.55
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Cuffless Blood Pressure Estimation Model Based on Prior Information of Physiological Data and LSTM — Peng Guo, Junjie Li, et al. · IEEE Sensors Journal (2024) | TGRS Research Map | TGRS