A Novel Broadband Dual-Frequency Circularly Polarized Implantable Antenna Empowering Future Intelligent Healthcare

Implantable medical devices (IMDs) have captured the attention of the scientific and industrial community due to their capacity to offer incessant, real-time physiological data for biomedical telemetry and electrotherapy through dynamic, accurate measurements, and stimulation. As the “eyes” of IMDs, multifunctional implantable antennas demand thorough research and design. A compact dual-band circularly polarized (CP) antenna system working at 1.4 –2.45 GHz, at wireless medical telemetry service (WMTS) band and industrial, scientific, and medical (ISM) band, is developed in this communication. By incorporating the technique of loading symmetric meandering slots and short-pins, the dimensions of the entire antenna are reduced to <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$8.8\times 8.8\times 0.508$ </tex-math></inline-formula> mm3. Simultaneously, based on the analysis of the current vectors and their superposition across various sections, it is demonstrated that the antenna exhibits right-hand circular polarization (RHCP) characteristics. To consider a practical operating scenario, the antenna was integrated with a battery and controlling electronics of a biocompatible shell. In the heterogeneous phantom, the proposed antenna showed a higher gain of −23.4, and −16 dBi at 1.4 GHz, and 2.45 GHz, respectively. This study represents the initial validation of the influence of diverse body types (varying fat content) on the frequency shift of the antenna. Additionally, we established the biological communication system of information through IMDs by employing a dual-band CP implantable antenna. To assess safety, the established invasive medical devices (IMDs) demonstrate in simulation results that the maximum specific absorption rate (SAR) value complies with the safety guidelines outlined by the IEEE standard.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2024-08-19
DOI
https://doi.org/10.1109/jsen.2024.3436544
Citations
8
Primary Topic
Wireless Body Area Networks
Type
article
Field-Weighted Citation Impact
1.48

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Novel Broadband Dual-Frequency Circularly Polarized Implantable Antenna Empowering Future Intelligent Healthcare

Pei Xiao, Gaosheng Li, Gui Gao, Xinyu Hu et al.
8 citations
IEEE Sensors Journal
Wireless Body Area Networks
1.48
article

A Novel Broadband Dual-Frequency Circularly Polarized Implantable Antenna Empowering Future Intelligent Healthcare

Pei Xiao, Gaosheng Li, Gui Gao, Xinyu Hu, Huan-huan Peng
article en
8 citations

Abstract

Implantable medical devices (IMDs) have captured the attention of the scientific and industrial community due to their capacity to offer incessant, real-time physiological data for biomedical telemetry and electrotherapy through dynamic, accurate measurements, and stimulation. As the “eyes” of IMDs, multifunctional implantable antennas demand thorough research and design. A compact dual-band circularly polarized (CP) antenna system working at 1.4 –2.45 GHz, at wireless medical telemetry service (WMTS) band and industrial, scientific, and medical (ISM) band, is developed in this communication. By incorporating the technique of loading symmetric meandering slots and short-pins, the dimensions of the entire antenna are reduced to <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$8.8\times 8.8\times 0.508$ </tex-math></inline-formula> mm3. Simultaneously, based on the analysis of the current vectors and their superposition across various sections, it is demonstrated that the antenna exhibits right-hand circular polarization (RHCP) characteristics. To consider a practical operating scenario, the antenna was integrated with a battery and controlling electronics of a biocompatible shell. In the heterogeneous phantom, the proposed antenna showed a higher gain of −23.4, and −16 dBi at 1.4 GHz, and 2.45 GHz, respectively. This study represents the initial validation of the influence of diverse body types (varying fat content) on the frequency shift of the antenna. Additionally, we established the biological communication system of information through IMDs by employing a dual-band CP implantable antenna. To assess safety, the established invasive medical devices (IMDs) demonstrate in simulation results that the maximum specific absorption rate (SAR) value complies with the safety guidelines outlined by the IEEE standard.

IEEE Sensors JournalVol. 24(19)
Hunan University (CN), Southwest Jiaotong University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 19%
Wireless Body Area Networks
1.48
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.