Development and validation of the UHPLC-MS/MS method for the quantitative determination of 25 PFAS in dried blood spots

Per- and polyfluoroalkyl substances (PFAS) are anthropogenic fluorine-containing compounds largely used in industrial and consumer applications. They tend to bioaccumulate in the human body after intake from various sources in daily life. Following repeated exposure to PFAS, a broad range of adverse health outcomes has been reported. Consequently, monitoring PFAS levels in human blood is of paramount importance for public health policies. In contrast with traditional venipuncture, dried blood spots (DBS) constitute a reliable, cheap, and less invasive technique to allow microsampling by capillary blood collected on a specific device. This work aimed to develop and validate an innovative analytical method, combining quantitative DBS with UHPLC-MS/MS instrumentation to identify and quantify 25 PFAS. The extraction procedure was developed and optimized within the range 2-100 ng/mL. Specifically, fortified blood was applied on Capitainer®B devices providing 10 μL of blood volume through a microfluidic channel. After 3 h of drying, the extraction was performed by methanol under sonication, followed by centrifugation. Then, the extraction solvent was evaporated; the residue was reconstituted with the mobile phase solution. The validated method evidenced good sensitivity, with limits of detection ranging from 0.4 ng/mL (PFODA, PFOS) to 1.0 ng/mL (PFOA, 3,6-OPFHpA). The ± 20% acceptability criteria established for intra- and inter-day precision and accuracy were fulfilled for all analytes. High recovery-above 80%-was recorded, whereas significant matrix effect resulted in ion enhancement (> 50%) for 13 analytes. In conclusion, the proposed workflow proved to be reliable, fit for purpose, and easily adaptable in the laboratory routine.

Authors

Institutions

Publication Details

Journal
Analytical and Bioanalytical Chemistry
Published
2024-08-19
DOI
https://doi.org/10.1007/s00216-024-05484-6
Citations
4
Primary Topic
Per- and polyfluoroalkyl substances research
Type
article
Field-Weighted Citation Impact
1.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and validation of the UHPLC-MS/MS method for the quantitative determination of 25 PFAS in dried blood spots

Alberto Salomone, Christina Ververi, Marco Vincenti, Marta Massano et al.
4 citations
Analytical and Bioanalytical Chemistry
Per- and polyfluoroalkyl substances research
1.00
article

Development and validation of the UHPLC-MS/MS method for the quantitative determination of 25 PFAS in dried blood spots

Alberto Salomone, Christina Ververi, Marco Vincenti, Marta Massano, Eugenio Alladio, Martina Galletto
article en
4 citations

Abstract

Per- and polyfluoroalkyl substances (PFAS) are anthropogenic fluorine-containing compounds largely used in industrial and consumer applications. They tend to bioaccumulate in the human body after intake from various sources in daily life. Following repeated exposure to PFAS, a broad range of adverse health outcomes has been reported. Consequently, monitoring PFAS levels in human blood is of paramount importance for public health policies. In contrast with traditional venipuncture, dried blood spots (DBS) constitute a reliable, cheap, and less invasive technique to allow microsampling by capillary blood collected on a specific device. This work aimed to develop and validate an innovative analytical method, combining quantitative DBS with UHPLC-MS/MS instrumentation to identify and quantify 25 PFAS. The extraction procedure was developed and optimized within the range 2-100 ng/mL. Specifically, fortified blood was applied on Capitainer®B devices providing 10 μL of blood volume through a microfluidic channel. After 3 h of drying, the extraction was performed by methanol under sonication, followed by centrifugation. Then, the extraction solvent was evaporated; the residue was reconstituted with the mobile phase solution. The validated method evidenced good sensitivity, with limits of detection ranging from 0.4 ng/mL (PFODA, PFOS) to 1.0 ng/mL (PFOA, 3,6-OPFHpA). The ± 20% acceptability criteria established for intra- and inter-day precision and accuracy were fulfilled for all analytes. High recovery-above 80%-was recorded, whereas significant matrix effect resulted in ion enhancement (> 50%) for 13 analytes. In conclusion, the proposed workflow proved to be reliable, fit for purpose, and easily adaptable in the laboratory routine.

Analytical and Bioanalytical ChemistryVol. 416(26)
University of Turin (IT)
Dipartimenti di Eccellenza, Università degli Studi di Torino
Openalex Percentile: Top 26%
Per- and polyfluoroalkyl substances research
1.00
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.