Si-implantation for low ohmic contact resistances in RF GaN HEMTs

Abstract In this work, Si implantation and activation for lowering the ohmic contact resistance ( R c ) of mm-wave GaN HEMTs has been investigated. Various combinations of annealing temperature/duration and implantation doses were tested. Dopant activation was performed using a modified procedure in an MOCVD tool, involving fast temperature ramping and annealing the samples for 8 min at 1150 °C. Thereby, ∼0.02 ± 0.01 Ω mm contact resistance was achieved on a fully doped region and ∼0.1 ± 0.02 Ω mm when only the source and drain contact region was n-type doped. For comparison, a well-established alloyed Ti/Al/Ni/Au ohmic contact scheme without implantation, was used as reference resulting in an average R c ∼ 0.34 ± 0.12 Ω mm on the same wafer. Besides the three times lowered contact resistance the implanted contacts also showed a significantly improved on-wafer homogeneity.

Authors

Institutions

Publication Details

Journal
Semiconductor Science and Technology
Published
2024-08-19
DOI
https://doi.org/10.1088/1361-6641/ad70d5
Citations
2
Primary Topic
GaN-based semiconductor devices and materials
Type
article
Field-Weighted Citation Impact
0.62

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Si-implantation for low ohmic contact resistances in RF GaN HEMTs

Hossein Yazdani, Hans-Joachim Würfl, F. Brunner, Oliver Hilt et al.
2 citations
Semiconductor Science and Technology
GaN-based semiconductor devices and materials
0.62
article

Si-implantation for low ohmic contact resistances in RF GaN HEMTs

Hossein Yazdani, Hans-Joachim Würfl, F. Brunner, Oliver Hilt, A. Thies
article en
2 citations

Abstract

Abstract In this work, Si implantation and activation for lowering the ohmic contact resistance ( R c ) of mm-wave GaN HEMTs has been investigated. Various combinations of annealing temperature/duration and implantation doses were tested. Dopant activation was performed using a modified procedure in an MOCVD tool, involving fast temperature ramping and annealing the samples for 8 min at 1150 °C. Thereby, ∼0.02 ± 0.01 Ω mm contact resistance was achieved on a fully doped region and ∼0.1 ± 0.02 Ω mm when only the source and drain contact region was n-type doped. For comparison, a well-established alloyed Ti/Al/Ni/Au ohmic contact scheme without implantation, was used as reference resulting in an average R c ∼ 0.34 ± 0.12 Ω mm on the same wafer. Besides the three times lowered contact resistance the implanted contacts also showed a significantly improved on-wafer homogeneity.

Semiconductor Science and TechnologyVol. 39(10)
Ferdinand-Braun-Institut (DE)
European Space Agency, Deutsche Forschungsgemeinschaft, Forschungsfabrik Mikroelektronik Deutschland
Clean water and sanitation
Openalex Percentile: Top 34%
GaN-based semiconductor devices and materials
0.62
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.