Development and Insulation Performance Evaluation of Experimental Sample for a Direct Current High-Voltage Transmission Line

For the negative-ion-based neutral beam injection system, the direct current (DC) high-voltage transmission line (HVTL) is the link between the radio frequency (RF) negative-ion source system and the power supply system, which not only realizes the function of the power transmission between the power supply system and the RF negative-ion source system, but also provides transmission channels for high-pressure cooling water, working gas, and the measurement and control signals needed for the operation of the RF negative-ion sources. In this study, the experimental sample for the DC HVTL is developed based on the insulation simulation design, and an insulation performance evaluation test bed of the experimental sample is designed and built. The insulation performances of the experimental sample at different SF6 gas pressures are investigated, and the leakage current laws of the experimental sample at different applied voltages and different SF6 gas pressures are obtained. The test results show that the maximum leakage current is 472 μA at a loading voltage of 500 kV, which proves that the experimental sample for the DC HVTL satisfies the requirements of the insulation design.

Authors

Institutions

Publication Details

Journal
Fusion Science & Technology
Published
2024-08-19
DOI
https://doi.org/10.1080/15361055.2024.2383089
Primary Topic
Particle accelerators and beam dynamics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and Insulation Performance Evaluation of Experimental Sample for a Direct Current High-Voltage Transmission Line

Wei Liu, Chundong Hu, Caichao Jiang, Rixin Wang et al.
3 links
Fusion Science & Technology
Particle accelerators and beam dynamics
article

Development and Insulation Performance Evaluation of Experimental Sample for a Direct Current High-Voltage Transmission Line

Wei Liu, Chundong Hu, Caichao Jiang, Rixin Wang, Jun Tao, Yongjian Xu, Lizhen Liang
article en

Abstract

For the negative-ion-based neutral beam injection system, the direct current (DC) high-voltage transmission line (HVTL) is the link between the radio frequency (RF) negative-ion source system and the power supply system, which not only realizes the function of the power transmission between the power supply system and the RF negative-ion source system, but also provides transmission channels for high-pressure cooling water, working gas, and the measurement and control signals needed for the operation of the RF negative-ion sources. In this study, the experimental sample for the DC HVTL is developed based on the insulation simulation design, and an insulation performance evaluation test bed of the experimental sample is designed and built. The insulation performances of the experimental sample at different SF6 gas pressures are investigated, and the leakage current laws of the experimental sample at different applied voltages and different SF6 gas pressures are obtained. The test results show that the maximum leakage current is 472 μA at a loading voltage of 500 kV, which proves that the experimental sample for the DC HVTL satisfies the requirements of the insulation design.

Fusion Science & TechnologyVol. 81(3)
Anhui University (CN), Chinese Academy of Sciences (CN), Hefei Institutes of Physical Science (CN), Institute of Plasma Physics (CN)
Affordable and clean energy
Openalex Percentile: Top 80%
Particle accelerators and beam dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Development and Insulation Performance Evaluation of Experimental Sample for a Direct Current High-Voltage Transmission Line — Wei Liu, Chundong Hu, et al. · Fusion Science & Technology (2024) | TGRS Research Map | TGRS