Optimization of a mass spectrometric analytical method for the quality assessment of insulin and its analogs.

The principal aim of this study was to optimize analytical methodology based on mass spectrometry for the evaluation of the quality of recombinant human insulin and its analogs. In this study ESI-MS was used to assess the quality of human insulin, short acting insulin analogs, insulin lispro, insulin aspart and insulin glulisine and long acting analogs including insulin glargine, insulin degludec, and insulin detemir, in respective pharmaceutical formulations. In this study, with the aimed to optimize analytical conditions, different factors influencing the analytical performance such as pH, ionic strength, sample dilution, organic solvent addition were addressed. The study results demonstrated that MS is a suitable technique for the analysis of biotechnological compounds like insulin and its analogs. Although the obtained results provide an important information regarding this methodology, further studies are needed to validate this analytical approach and check for its suitability to be used in the regulatory environment.

Authors

Institutions

Publication Details

Journal
PubMed
Published
2024-08-01
DOI
https://doi.org/10.1691/ph.2024.4013
Primary Topic
Analytical Chemistry and Chromatography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization of a mass spectrometric analytical method for the quality assessment of insulin and its analogs.

Dashnor Nebija, Blerta Pajaziti, Melinda Andrási, N Kemlendi
PubMed
Analytical Chemistry and Chromatography
article

Optimization of a mass spectrometric analytical method for the quality assessment of insulin and its analogs.

Dashnor Nebija, Blerta Pajaziti, Melinda Andrási, N Kemlendi
article en

Abstract

The principal aim of this study was to optimize analytical methodology based on mass spectrometry for the evaluation of the quality of recombinant human insulin and its analogs. In this study ESI-MS was used to assess the quality of human insulin, short acting insulin analogs, insulin lispro, insulin aspart and insulin glulisine and long acting analogs including insulin glargine, insulin degludec, and insulin detemir, in respective pharmaceutical formulations. In this study, with the aimed to optimize analytical conditions, different factors influencing the analytical performance such as pH, ionic strength, sample dilution, organic solvent addition were addressed. The study results demonstrated that MS is a suitable technique for the analysis of biotechnological compounds like insulin and its analogs. Although the obtained results provide an important information regarding this methodology, further studies are needed to validate this analytical approach and check for its suitability to be used in the regulatory environment.

PubMedVol. 79(7)
University of Prishtina (XK)
Openalex Percentile: Top 90%
Analytical Chemistry and Chromatography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.