Assessment of necessity for implementing heating, ventilation, and air conditioning systems in churches of Armenia

In continental climatic conditions, ensuring the thermal comfort of buildings of historical, architectural, and cultural heritage is associated with several difficulties. Buildings and churches that stood for thousands of years, were not cooled or heated but had design features that ensure constant thermal comfort inside, regardless of fluctuations in external climatic conditions. Passive heating was also used in such buildings, for example, in the hot season, massive buildings accumulated heat gain and then gave off heat in the cold season. When restoring historical buildings and churches, we often encounter the need to introduce air conditioning, ventilation, and heating systems, which must provide the microclimate of the premises that meets modern requirements for thermal comfort and energy efficiency. However, such interventions can also have negative consequences since the requirements for the thermal comfort of parishioners and the architectural and historical conceptual integrity of a given building often contradict each other. To solve this problem, collaborative interdisciplinary research is needed to minimize the impact of mechanical heating and air conditioning systems. An evaluation of the suitability of the heating and cooling systems of existing and renovated churches in Armenia was carried out by monitoring the temperature and humidity of the indoor and outdoor air, analyzing the factors that provide comfortable conditions for the people there. It has been proven that conditions providing thermal comfort to people can be achieved without the introduction of HVAC systems. For this purpose, factors providing passive heating or cooling, such as existing natural ventilation opportunities, prevailing wind direction and speed, building materials and thermal mass, etc., were evaluated. An example of the implementation of HVAC systems is described, in which the invasive effect on the originality of the historic building is minimized.

Authors

Institutions

Publication Details

Journal
Multidisciplinary Reviews
Published
2024-08-16
DOI
https://doi.org/10.31893/multirev.2024ss006
Primary Topic
Conservation Techniques and Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of necessity for implementing heating, ventilation, and air conditioning systems in churches of Armenia

Anna Karamyan
Multidisciplinary Reviews
Conservation Techniques and Studies
article

Assessment of necessity for implementing heating, ventilation, and air conditioning systems in churches of Armenia

Anna Karamyan
article en

Abstract

In continental climatic conditions, ensuring the thermal comfort of buildings of historical, architectural, and cultural heritage is associated with several difficulties. Buildings and churches that stood for thousands of years, were not cooled or heated but had design features that ensure constant thermal comfort inside, regardless of fluctuations in external climatic conditions. Passive heating was also used in such buildings, for example, in the hot season, massive buildings accumulated heat gain and then gave off heat in the cold season. When restoring historical buildings and churches, we often encounter the need to introduce air conditioning, ventilation, and heating systems, which must provide the microclimate of the premises that meets modern requirements for thermal comfort and energy efficiency. However, such interventions can also have negative consequences since the requirements for the thermal comfort of parishioners and the architectural and historical conceptual integrity of a given building often contradict each other. To solve this problem, collaborative interdisciplinary research is needed to minimize the impact of mechanical heating and air conditioning systems. An evaluation of the suitability of the heating and cooling systems of existing and renovated churches in Armenia was carried out by monitoring the temperature and humidity of the indoor and outdoor air, analyzing the factors that provide comfortable conditions for the people there. It has been proven that conditions providing thermal comfort to people can be achieved without the introduction of HVAC systems. For this purpose, factors providing passive heating or cooling, such as existing natural ventilation opportunities, prevailing wind direction and speed, building materials and thermal mass, etc., were evaluated. An example of the implementation of HVAC systems is described, in which the invasive effect on the originality of the historic building is minimized.

Multidisciplinary ReviewsVol. 7
National University of Architecture and Construction of Armenia (AM)
Affordable and clean energy
Openalex Percentile: Top 81%
Conservation Techniques and Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Assessment of necessity for implementing heating, ventilation, and air conditioning systems in churches of Armenia — Anna Karamyan · Multidisciplinary Reviews (2024) | TGRS Research Map | TGRS