Proton and Carbon-Ion Minibeam Therapy: From Modeling to Treatment

Arrays of minibeams of protons and 12C in tissue-like media were modeled with Geant4 toolkit. A set of beam energies was used in simulations to provide a Spead-out Bragg peak (SOBP) extended by 6 cm in depth for protons as well as for 12C. In both cases, beams of 0.3 or 0.5 mm FWHM were arranged at the entrance to a water phantom either on a rectangular or an hexagonal grid to compare two kinds of projectiles and different minibeam patterns. Differential and cumulative dose-volume histograms (DVH) were calculated and compared for protons and 12C as dose uniformity metrics. A uniform dose distribution was easily achieved with protons due to an enhanced lateral scattering of these projectiles in comparison to 12C. The cumulative DVHs calculated for 0.3 or 0.5 mm minibeams almost coincide in the target volume, but diverge for different grid patterns. In contrast, cumulative entry DVHs were found similar for both grid patterns, but different for 0.3 and 0.5 mm minibeams.

Authors

Institutions

Publication Details

Journal
Physics of Particles and Nuclei
Published
2024-08-01
DOI
https://doi.org/10.1134/s1063779624700606
Citations
3
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
1.26
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Proton and Carbon-Ion Minibeam Therapy: From Modeling to Treatment

Aleksandr Svetlichnyi, I. Pshenichnov, S. D. Savenkov, U. Dmitrieva
3 citations
Physics of Particles and Nuclei
Radiation Therapy and Dosimetry
1.26
article

Proton and Carbon-Ion Minibeam Therapy: From Modeling to Treatment

Aleksandr Svetlichnyi, I. Pshenichnov, S. D. Savenkov, U. Dmitrieva
article en
3 citations

Abstract

Arrays of minibeams of protons and 12C in tissue-like media were modeled with Geant4 toolkit. A set of beam energies was used in simulations to provide a Spead-out Bragg peak (SOBP) extended by 6 cm in depth for protons as well as for 12C. In both cases, beams of 0.3 or 0.5 mm FWHM were arranged at the entrance to a water phantom either on a rectangular or an hexagonal grid to compare two kinds of projectiles and different minibeam patterns. Differential and cumulative dose-volume histograms (DVH) were calculated and compared for protons and 12C as dose uniformity metrics. A uniform dose distribution was easily achieved with protons due to an enhanced lateral scattering of these projectiles in comparison to 12C. The cumulative DVHs calculated for 0.3 or 0.5 mm minibeams almost coincide in the target volume, but diverge for different grid patterns. In contrast, cumulative entry DVHs were found similar for both grid patterns, but different for 0.3 and 0.5 mm minibeams.

Physics of Particles and NucleiVol. 55(4)
Institute for Nuclear Research (RU)
Openalex Percentile: Top 19%
Radiation Therapy and Dosimetry
1.26
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.