Who Says You can’t go FAST at Night? Use of a Novel Ultrasound-Capable Night Vision Device for Prehospital Medical Personnel to Identify Noncompressible Truncal Hemorrhage

Background Early detection of abdominal hemorrhage via ultrasound has life-saving implications for military and civilian trauma. However, strict adherence to light discipline may prohibit the use of ultrasound devices in the deployed setting. Additionally, current night vision devices remain noncompatible with ultrasound technology. This study sought to assess an innovative night vision device with ultrasound capable picture-in-picture display via a intraabdominal hemorrhage model to identify noncompressible truncal hemorrhage in blackout conditions. Methods 8 post mortem fetal porcine specimens were used and divided into 2 groups: intrabdominal hemorrhage (n = 4) vs no hemorrhage (n = 4). Intrabdominal hemorrhage was modeled via direct injection of 200 mL of normal saline into the peritoneal cavity. Under blackout conditions, 5 participants performed a focused assessment with sonography for trauma (FAST) exam on each model using the prototype ultrasound-capable night vision device. Results Of the 40 FAST exams performed, 95% (N = 38) resulted in the correct identification of intraabdominal hemorrhage. Of the incorrectly identified exams, both were false positives resulting in a 100% sensitivity, 90% specificity, 91% positive predictive value, and a 100% negative predictive value. All participants noted the novel device was easy to use and provided superior visualization for performing FAST exams under blackout conditions. Conclusion The ultrasound-enabled night vision prototype demonstrated promising results in identifying noncompressible truncal hemorrhage while maintaining strict light discipline in blackout conditions. Further research efforts should be directed at assessing the ability of providers to perform procedures in blackout conditions using the ultrasound-enabled prototype night vision device.

Authors

Institutions

Publication Details

Journal
Surgical Innovation
Published
2024-08-16
DOI
https://doi.org/10.1177/15533506241275288
Primary Topic
Ultrasound in Clinical Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Who Says You can’t go FAST at Night? Use of a Novel Ultrasound-Capable Night Vision Device for Prehospital Medical Personnel to Identify Noncompressible Truncal Hemorrhage

Beau Prey, Daniel Lammers, Andrew D Francis, John M. McClellan et al.
Surgical Innovation
Ultrasound in Clinical Applications
article

Who Says You can’t go FAST at Night? Use of a Novel Ultrasound-Capable Night Vision Device for Prehospital Medical Personnel to Identify Noncompressible Truncal Hemorrhage

Beau Prey, Daniel Lammers, Andrew D Francis, John M. McClellan, James Williams, Jason Bingham, Matthew J. Eckert, Luke Pumiglia, Yang Liu
article en

Abstract

Background Early detection of abdominal hemorrhage via ultrasound has life-saving implications for military and civilian trauma. However, strict adherence to light discipline may prohibit the use of ultrasound devices in the deployed setting. Additionally, current night vision devices remain noncompatible with ultrasound technology. This study sought to assess an innovative night vision device with ultrasound capable picture-in-picture display via a intraabdominal hemorrhage model to identify noncompressible truncal hemorrhage in blackout conditions. Methods 8 post mortem fetal porcine specimens were used and divided into 2 groups: intrabdominal hemorrhage (n = 4) vs no hemorrhage (n = 4). Intrabdominal hemorrhage was modeled via direct injection of 200 mL of normal saline into the peritoneal cavity. Under blackout conditions, 5 participants performed a focused assessment with sonography for trauma (FAST) exam on each model using the prototype ultrasound-capable night vision device. Results Of the 40 FAST exams performed, 95% (N = 38) resulted in the correct identification of intraabdominal hemorrhage. Of the incorrectly identified exams, both were false positives resulting in a 100% sensitivity, 90% specificity, 91% positive predictive value, and a 100% negative predictive value. All participants noted the novel device was easy to use and provided superior visualization for performing FAST exams under blackout conditions. Conclusion The ultrasound-enabled night vision prototype demonstrated promising results in identifying noncompressible truncal hemorrhage while maintaining strict light discipline in blackout conditions. Further research efforts should be directed at assessing the ability of providers to perform procedures in blackout conditions using the ultrasound-enabled prototype night vision device.

Surgical InnovationVol. 31(6)
University of North Carolina at Chapel Hill (US), University of Iowa (US), Madigan Army Medical Center (US), University of Alabama at Birmingham (US)
Openalex Percentile: Top 83%
Ultrasound in Clinical Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.