Quantitative spectral micro-CT of a CA4+ loaded osteochondral sample with a tabletop system

Abstract Micro-computed tomography ( $$\upmu$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mi>μ</mml:mi> </mml:math> CT) is the gold standard for nondestructive 3D imaging of biomedical samples in the centimeter scale, but it has limited effectiveness in revealing intricate soft tissue details due to the limited attenuation contrast. Radiopaque contrast agents that accumulate in the structures of interest are employed to enhance their visibility. However, the increased attenuation provided by the contrast agents does not guarantee discrimination among tissues. This issue can be solved by spectral $$\upmu$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mi>μ</mml:mi> </mml:math> CT (S $$\upmu$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mi>μ</mml:mi> </mml:math> CT) systems employing small-pixel chromatic photon-counting detectors. These detectors, combined with material decomposition algorithms, allow the generation of high-resolution material-specific 3D maps. This work aims to demonstrate the potential of photon-counting X-ray S $$\upmu$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mi>μ</mml:mi> </mml:math> CT on osteochondral samples loaded with a cationic iodinated contrast agent (CA4+) at a spatial resolution below 50 $$\upmu$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mi>μ</mml:mi> </mml:math> m, and to compare the results against a conventional $$\upmu$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mi>μ</mml:mi> </mml:math> CT system. An osteochondral sample extracted from a bovine stifle joint was loaded with CA4+ and imaged with a novel multimodal X-ray imaging system, featuring a 62 $$\upmu$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mi>μ</mml:mi> </mml:math> m pixel CdTe spectral detector (Pixirad1-PixieIII). After material decomposition, quantitative 3D density maps of iodine and hydroxyapatite were reconstructed. The same sample was also scanned with a commercial $$\upmu$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mi>μ</mml:mi> </mml:math> CT scanner with matched spectrum and exposure time. SCT $$\upmu$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mi>μ</mml:mi> </mml:math> images at a (measured) spatial resolution comparable with the commercial scanner ( $$\sim$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mo>∼</mml:mo> </mml:math> 45 $$\upmu$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mi>μ</mml:mi> </mml:math> m) were obtained. Spectral images allowed for a fully automatic segmentation of cartilage and subchondral bone. The unambiguous discrimination between iodine and hydroxyapatite revealed a more realistic representation of proteoglycan distribution compared to conventional imaging.

Authors

Institutions

Publication Details

Journal
The European Physical Journal Plus
Published
2024-08-16
DOI
https://doi.org/10.1140/epjp/s13360-024-05428-0
Citations
3
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.55

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantitative spectral micro-CT of a CA4+ loaded osteochondral sample with a tabletop system

Francesco Brun, P. Cardarelli, Simone Fantoni, Luca Brombal et al.
3 citations
The European Physical Journal Plus
Advanced X-ray and CT Imaging
0.55
article

Quantitative spectral micro-CT of a CA4+ loaded osteochondral sample with a tabletop system

Francesco Brun, P. Cardarelli, Simone Fantoni, Luca Brombal, Angelo Taibi, Fabio Baruffaldi, Virginia Cristofori, Claudio Trapella
article en
3 citations

Abstract

Abstract Micro-computed tomography ( $$\upmu$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mi>μ</mml:mi> </mml:math> CT) is the gold standard for nondestructive 3D imaging of biomedical samples in the centimeter scale, but it has limited effectiveness in revealing intricate soft tissue details due to the limited attenuation contrast. Radiopaque contrast agents that accumulate in the structures of interest are employed to enhance their visibility. However, the increased attenuation provided by the contrast agents does not guarantee discrimination among tissues. This issue can be solved by spectral $$\upmu$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mi>μ</mml:mi> </mml:math> CT (S $$\upmu$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mi>μ</mml:mi> </mml:math> CT) systems employing small-pixel chromatic photon-counting detectors. These detectors, combined with material decomposition algorithms, allow the generation of high-resolution material-specific 3D maps. This work aims to demonstrate the potential of photon-counting X-ray S $$\upmu$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mi>μ</mml:mi> </mml:math> CT on osteochondral samples loaded with a cationic iodinated contrast agent (CA4+) at a spatial resolution below 50 $$\upmu$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mi>μ</mml:mi> </mml:math> m, and to compare the results against a conventional $$\upmu$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mi>μ</mml:mi> </mml:math> CT system. An osteochondral sample extracted from a bovine stifle joint was loaded with CA4+ and imaged with a novel multimodal X-ray imaging system, featuring a 62 $$\upmu$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mi>μ</mml:mi> </mml:math> m pixel CdTe spectral detector (Pixirad1-PixieIII). After material decomposition, quantitative 3D density maps of iodine and hydroxyapatite were reconstructed. The same sample was also scanned with a commercial $$\upmu$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mi>μ</mml:mi> </mml:math> CT scanner with matched spectrum and exposure time. SCT $$\upmu$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mi>μ</mml:mi> </mml:math> images at a (measured) spatial resolution comparable with the commercial scanner ( $$\sim$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mo>∼</mml:mo> </mml:math> 45 $$\upmu$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mi>μ</mml:mi> </mml:math> m) were obtained. Spectral images allowed for a fully automatic segmentation of cartilage and subchondral bone. The unambiguous discrimination between iodine and hydroxyapatite revealed a more realistic representation of proteoglycan distribution compared to conventional imaging.

The European Physical Journal PlusVol. 139(8)
University of Trieste (IT), University of Ferrara (IT), Istituto Nazionale di Fisica Nucleare, Sezione di Ferrara (IT), Istituto Ortopedico Rizzoli (IT), Istituto Nazionale di Fisica Nucleare, Sezione di Trieste (IT)
European Commission, Istituto Ortopedico Rizzoli di Bologna, Università degli Studi di Trieste, Nuclear Physics, Commissione Scientifica Nazionale 5, Instituto Nazionale di Fisica Nucleare
Reduced inequalities, Peace, Justice and strong institutions
Openalex Percentile: Top 38%
Advanced X-ray and CT Imaging
0.55
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.