Interlaboratory comparison of phosphatidylethanol in dried blood spots using different sampling devices

Phosphatidylethanol (PEth) has become an important marker to assess drinking behaviour and monitor abstinence. Despite its increasing use, knowledge on robustness and standardization and comparability of methods and results are still limited. In 2022, the first international consensus for the use of PEth and its interpretation was published. To establish an experience-based foundation for further harmonization, three rounds of interlaboratory comparison using microsamples were conducted. Participating laboratories sent their sampling devices to the laboratory of Forensic Toxicology at the University of Bern, where for each round, four different authentic blood samples were applied to the devices and sent back. The PEth 16:0/18:1 target concentrations covered a range between 16 and 474 ng/mL (0.023 and 0.676 μmol/L, respectively) and included sample concentrations close to the decision limits of 20 and 200 ng/mL (0.025 and 0.28 μmol/L, respectively). Evaluation of the results based on guidelines by Horwitz and the Society of Toxicological and Forensic Chemistry (GTFCh) showed that 73% of all participating laboratories quantified and reported all samples (N = 4 for each round) within the acceptable limits. More than 90% quantified and reported at least one sample within the acceptable limits.

Authors

Institutions

Publication Details

Journal
Drug Testing and Analysis
Published
2024-08-16
DOI
https://doi.org/10.1002/dta.3784
Citations
4
Primary Topic
Biosimilars and Bioanalytical Methods
Type
article
Field-Weighted Citation Impact
0.96
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Interlaboratory comparison of phosphatidylethanol in dried blood spots using different sampling devices

Marc Luginbühl, Wolfgang Weinmann, Frederike Stöth, Matthias Bantle
4 citations
Drug Testing and Analysis
Biosimilars and Bioanalytical Methods
0.96
article

Interlaboratory comparison of phosphatidylethanol in dried blood spots using different sampling devices

Marc Luginbühl, Wolfgang Weinmann, Frederike Stöth, Matthias Bantle
article en
4 citations

Abstract

Phosphatidylethanol (PEth) has become an important marker to assess drinking behaviour and monitor abstinence. Despite its increasing use, knowledge on robustness and standardization and comparability of methods and results are still limited. In 2022, the first international consensus for the use of PEth and its interpretation was published. To establish an experience-based foundation for further harmonization, three rounds of interlaboratory comparison using microsamples were conducted. Participating laboratories sent their sampling devices to the laboratory of Forensic Toxicology at the University of Bern, where for each round, four different authentic blood samples were applied to the devices and sent back. The PEth 16:0/18:1 target concentrations covered a range between 16 and 474 ng/mL (0.023 and 0.676 μmol/L, respectively) and included sample concentrations close to the decision limits of 20 and 200 ng/mL (0.025 and 0.28 μmol/L, respectively). Evaluation of the results based on guidelines by Horwitz and the Society of Toxicological and Forensic Chemistry (GTFCh) showed that 73% of all participating laboratories quantified and reported all samples (N = 4 for each round) within the acceptable limits. More than 90% quantified and reported at least one sample within the acceptable limits.

Drug Testing and AnalysisVol. 17(6)
University of Bern (CH), University Hospital of Zurich (CH)
Good health and well-being
Openalex Percentile: Top 25%
Biosimilars and Bioanalytical Methods
0.96
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Interlaboratory comparison of phosphatidylethanol in dried blood spots using different sampling devices — Marc Luginbühl, Wolfgang Weinmann, et al. · Drug Testing and Analysis (2024) | TGRS Research Map | TGRS