Experimental investigation of laminar forced convection along flat tubes with longitudinal fins

The present work experimentally investigates laminar forced convection in staggered finned-flat tubes bank. The study is based on dimensionless downstream fins length, i.e. = 0.4, 0.6, 0.8, and 1, and Reynolds number (Re) range from 223 to 1114. The study was conducted under dimensionless transverse pitch ( = 3.0), longitudinal pitch ( = 4.0), upstream fin length ( = 8), and fin angle (θ = 30°). As the dimensionless downstream fins length increased from 0.4 to 1.0, the dimensionless heat transfer rate was improved up to 6.7%, the dimensionless pressure drop significantly increased up to 225%, and the thermal-hydraulic performance decreased up to 68.5%.

Authors

Institutions

Publication Details

Journal
Experimental Heat Transfer
Published
2024-08-15
DOI
https://doi.org/10.1080/08916152.2024.2392819
Citations
4
Primary Topic
Heat Transfer and Optimization
Type
article
Field-Weighted Citation Impact
0.85
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental investigation of laminar forced convection along flat tubes with longitudinal fins

Maki H. Zaidan, Manar Al-Jethelah, Ahmed H. Ahmed
4 citations
Experimental Heat Transfer
Heat Transfer and Optimization
0.85
article

Experimental investigation of laminar forced convection along flat tubes with longitudinal fins

Maki H. Zaidan, Manar Al-Jethelah, Ahmed H. Ahmed
article en
4 citations

Abstract

The present work experimentally investigates laminar forced convection in staggered finned-flat tubes bank. The study is based on dimensionless downstream fins length, i.e. = 0.4, 0.6, 0.8, and 1, and Reynolds number (Re) range from 223 to 1114. The study was conducted under dimensionless transverse pitch ( = 3.0), longitudinal pitch ( = 4.0), upstream fin length ( = 8), and fin angle (θ = 30°). As the dimensionless downstream fins length increased from 0.4 to 1.0, the dimensionless heat transfer rate was improved up to 6.7%, the dimensionless pressure drop significantly increased up to 225%, and the thermal-hydraulic performance decreased up to 68.5%.

Experimental Heat TransferVol. 38(6)
Northern Technical University (IQ), University of Tikrit (IQ)
Climate action
Openalex Percentile: Top 31%
Heat Transfer and Optimization
0.85
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.