Size-controlled synthesis of cobalt phosphide (Co2P) nanoparticles and their application in non-enzymatic glucose sensors via a carbon fiber/Co2P composite

In this study, we synthesized Co 2 P nanoparticles using a solid-state phosphorization method and evaluated the electrocatalytic response to glucose oxidation reaction (GORs). The influence of synthesis conditions on the particle size, morphology of Co 2 P species and formation of byproducts is discussed. A lower molar ratio of the phosphorus precursor leads to a decrease in the generation of byproducts. In addition, the calcination temperature and time greatly influence the purity level of the Co 2 P species and its particle size. Thus, we obtained three pure Co 2 P nanoparticles with different sizes and morphologies. Significant differences in their electrocatalytic activity against the GOR are observed depending on the size of the particles, being the smaller ones the most efficient. Based on Tafel analysis, a higher catalytic activity was observed for the carbon fibre (CF)/Co 2 P composite compared to Co 2 P, which presented a greater onset potential and low response in current density. Tafel slopes close to 120 mV/dec were obtained for both materials, indicating that the mechanism is independent of the type of Co 2 P-based material used. Finally, the performance of the GCE/CF/Co 2 P sensor was demonstrated by amperometric measurements, with a sensitivity of 409 µAmM -1 cm -2 , a linear range between 39.4 µM and 150 µM, and a detection limit of 0.97 µM, analytical characteristics better than those obtained for other cobalt phosphide-based sensors reported in the literature. In addition, the GCE/CF/Co 2 P sensor shows excellent selectivity and demonstrated to be competitive compared to other Co-based non-enzymatic glucose sensors.

Authors

Institutions

Publication Details

Journal
Sensors and Actuators Reports
Published
2024-08-16
DOI
https://doi.org/10.1016/j.snr.2024.100235
Citations
4
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.83
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Size-controlled synthesis of cobalt phosphide (Co2P) nanoparticles and their application in non-enzymatic glucose sensors via a carbon fiber/Co2P composite

Claudia Yáñez, Tania P. Brito, Andrónico Neira‐Carrillo, Nicole Butto-Miranda et al.
4 citations
Sensors and Actuators Reports
Electrochemical sensors and biosensors
0.83
article

Size-controlled synthesis of cobalt phosphide (Co2P) nanoparticles and their application in non-enzymatic glucose sensors via a carbon fiber/Co2P composite

Claudia Yáñez, Tania P. Brito, Andrónico Neira‐Carrillo, Nicole Butto-Miranda, D. Ruiz, Soledad Bollo
article en
4 citations

Abstract

In this study, we synthesized Co 2 P nanoparticles using a solid-state phosphorization method and evaluated the electrocatalytic response to glucose oxidation reaction (GORs). The influence of synthesis conditions on the particle size, morphology of Co 2 P species and formation of byproducts is discussed. A lower molar ratio of the phosphorus precursor leads to a decrease in the generation of byproducts. In addition, the calcination temperature and time greatly influence the purity level of the Co 2 P species and its particle size. Thus, we obtained three pure Co 2 P nanoparticles with different sizes and morphologies. Significant differences in their electrocatalytic activity against the GOR are observed depending on the size of the particles, being the smaller ones the most efficient. Based on Tafel analysis, a higher catalytic activity was observed for the carbon fibre (CF)/Co 2 P composite compared to Co 2 P, which presented a greater onset potential and low response in current density. Tafel slopes close to 120 mV/dec were obtained for both materials, indicating that the mechanism is independent of the type of Co 2 P-based material used. Finally, the performance of the GCE/CF/Co 2 P sensor was demonstrated by amperometric measurements, with a sensitivity of 409 µAmM -1 cm -2 , a linear range between 39.4 µM and 150 µM, and a detection limit of 0.97 µM, analytical characteristics better than those obtained for other cobalt phosphide-based sensors reported in the literature. In addition, the GCE/CF/Co 2 P sensor shows excellent selectivity and demonstrated to be competitive compared to other Co-based non-enzymatic glucose sensors.

Sensors and Actuators ReportsVol. 8
Universidad de Santiago de Chile (CL), Instituto de Ciências Farmacêuticas (BR), University of Chile (CL)
Openalex Percentile: Top 27%
Electrochemical sensors and biosensors
0.83
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.