Printed potentiometric, non-enzymatic sensors based on Zr(IV)-porphyrins for determination of lactate

The feasibility of using Zr-porphyrins as ionophores selective towards lactate ions was examined. Zr-tetraphenylporphyrin (Zr-TPP) and Zr-octaethylporphyrin (Zr-OEP) were tested in polyurethane membranes plasticized with dioctyl sebacate or o-nitrophenyl ether and containing cationic or anionic lipophilic sites, respectively. The best lactate response characteristics were registered for membrane plasticized with dioctyl sebacate and doped with Zr-TPP and cationic lipophilic sites. Classical electrodes with this membrane showed high selectivity towards lactate ions with a sensitivity of −76.6 mV dec −1 and linear lactate calibration range from 10 −4 M to 10 −1 M. Polymeric membranes containing Zr-TPP were then drop-casted on screen-printed transducers with electrodes made of graphene-containing paste. It was found that the potentiometric behavior of these miniature planar sensors is very similar to classical electrodes. In the next step, fully printed sensors, with both graphene electrodes and ion-selective polymeric membranes, were fabricated using aerosol jet printing. The sensitivity of these electrodes towards lactate was −79.01±0.39 mV dec −1 with a linear response range from 10 −3.5 M to 10 −1 M and a fast response to lactate concentration changes. The proposed electrode demonstrates a rare example of a potentiometric, non-enzymatic sensor for the determination of lactate ions, with the possibility of miniaturization and mass fabrication using printing methods. • Zr-porphyrins show high selectivity towards lactate ion in polyurethane membranes. • Both neutral carrier and charged carrier mechanism are possible for these ionophores. • Fully printed, planar sensors for lactate determination were developed. • A rare example of potentiometric, non-enzymatic lactate sensor was proposed.

Authors

Institutions

Publication Details

Journal
Sensors and Actuators B Chemical
Published
2024-08-16
DOI
https://doi.org/10.1016/j.snb.2024.136475
Citations
3
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.87
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Printed potentiometric, non-enzymatic sensors based on Zr(IV)-porphyrins for determination of lactate

Jan Dominiczak, Łukasz Górski, Andrzej Pepłowski, Jakub Krzemiński et al.
3 citations
Sensors and Actuators B Chemical
Analytical Chemistry and Sensors
0.87
article

Printed potentiometric, non-enzymatic sensors based on Zr(IV)-porphyrins for determination of lactate

Jan Dominiczak, Łukasz Górski, Andrzej Pepłowski, Jakub Krzemiński, Justyna Wojcieszek, Izabela Wojciechowska
article en
3 citations

Abstract

The feasibility of using Zr-porphyrins as ionophores selective towards lactate ions was examined. Zr-tetraphenylporphyrin (Zr-TPP) and Zr-octaethylporphyrin (Zr-OEP) were tested in polyurethane membranes plasticized with dioctyl sebacate or o-nitrophenyl ether and containing cationic or anionic lipophilic sites, respectively. The best lactate response characteristics were registered for membrane plasticized with dioctyl sebacate and doped with Zr-TPP and cationic lipophilic sites. Classical electrodes with this membrane showed high selectivity towards lactate ions with a sensitivity of −76.6 mV dec −1 and linear lactate calibration range from 10 −4 M to 10 −1 M. Polymeric membranes containing Zr-TPP were then drop-casted on screen-printed transducers with electrodes made of graphene-containing paste. It was found that the potentiometric behavior of these miniature planar sensors is very similar to classical electrodes. In the next step, fully printed sensors, with both graphene electrodes and ion-selective polymeric membranes, were fabricated using aerosol jet printing. The sensitivity of these electrodes towards lactate was −79.01±0.39 mV dec −1 with a linear response range from 10 −3.5 M to 10 −1 M and a fast response to lactate concentration changes. The proposed electrode demonstrates a rare example of a potentiometric, non-enzymatic sensor for the determination of lactate ions, with the possibility of miniaturization and mass fabrication using printing methods. • Zr-porphyrins show high selectivity towards lactate ion in polyurethane membranes. • Both neutral carrier and charged carrier mechanism are possible for these ionophores. • Fully printed, planar sensors for lactate determination were developed. • A rare example of potentiometric, non-enzymatic lactate sensor was proposed.

Sensors and Actuators B ChemicalVol. 421
Warsaw University of Technology (PL), Medical University of Warsaw (PL)
Zero hunger
Openalex Percentile: Top 31%
Analytical Chemistry and Sensors
0.87
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.