Long-Term Permissible Load Currents of Single-Core Cables with a Voltage of 10 kV with Cross-Linked Polyethylene Insulation of Various Designs

There is a large number of factors that affect the long-term permissible load currents of power cables, including environmental conditions, the method of laying, as well as the geometric, thermal and electrical characteristics of the cable structure. The catalogs of manufacturers of power cables with cross-linked polyethylene insulation do not specify the long-term permissible load currents, which would take into account the cross-sectional area of the screen, the presence of aluminum polymer tape and armor made of aluminum wires. These components can have a significant impact on the permissible load due to the currents induced in them during two-way grounding, which leads to additional heating of the cable. The purpose of this study is to analyze the influence of the above-mentioned factors on the long-term permissible load currents. The paper presents formulas for calculating the long-term permissible load current, which take into account the design features of the cables under consideration. The calculations have shown that the permissible load can decrease by 6 % with an increase in the cross-sectional area of the screen from the nominal row by one step. The introduction of an aluminum polymer tape into the cable structure changes the permissible load by no more than 2 %. The presence of armor can lead to a decrease in the permissible load by up to 18 % and its increase by up to 13 %, depending on the section of the core and screen, the method and conditions of laying. The calculation results obtained differ from the catalogdata by up to 25%. While the obtained errorsindicatetheneed to formcoefficientsfor a moreaccuratedetermination of the long-term permissible cable currents.

Authors

Institutions

Publication Details

Journal
ENERGETIKA Proceedings of CIS higher education institutions and power engineering associations
Published
2024-08-12
DOI
https://doi.org/10.21122/1029-7448-2024-67-4-300-314
Citations
1
Primary Topic
Thermal Analysis in Power Transmission
Type
article
Field-Weighted Citation Impact
0.33
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Long-Term Permissible Load Currents of Single-Core Cables with a Voltage of 10 kV with Cross-Linked Polyethylene Insulation of Various Designs

M. E. Vysotski
1 citations
ENERGETIKA Proceedings of CIS higher education institutions and power engineering associations
Thermal Analysis in Power Transmission
0.33
article

Long-Term Permissible Load Currents of Single-Core Cables with a Voltage of 10 kV with Cross-Linked Polyethylene Insulation of Various Designs

M. E. Vysotski
article en
1 citations

Abstract

There is a large number of factors that affect the long-term permissible load currents of power cables, including environmental conditions, the method of laying, as well as the geometric, thermal and electrical characteristics of the cable structure. The catalogs of manufacturers of power cables with cross-linked polyethylene insulation do not specify the long-term permissible load currents, which would take into account the cross-sectional area of the screen, the presence of aluminum polymer tape and armor made of aluminum wires. These components can have a significant impact on the permissible load due to the currents induced in them during two-way grounding, which leads to additional heating of the cable. The purpose of this study is to analyze the influence of the above-mentioned factors on the long-term permissible load currents. The paper presents formulas for calculating the long-term permissible load current, which take into account the design features of the cables under consideration. The calculations have shown that the permissible load can decrease by 6 % with an increase in the cross-sectional area of the screen from the nominal row by one step. The introduction of an aluminum polymer tape into the cable structure changes the permissible load by no more than 2 %. The presence of armor can lead to a decrease in the permissible load by up to 18 % and its increase by up to 13 %, depending on the section of the core and screen, the method and conditions of laying. The calculation results obtained differ from the catalogdata by up to 25%. While the obtained errorsindicatetheneed to formcoefficientsfor a moreaccuratedetermination of the long-term permissible cable currents.

ENERGETIKA Proceedings of CIS higher education institutions and power engineering associationsVol. 67(4)
Belarusian National Technical University (BY)
Openalex Percentile: Top 43%
Thermal Analysis in Power Transmission
0.33
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Long-Term Permissible Load Currents of Single-Core Cables with a Voltage of 10 kV with Cross-Linked Polyethylene Insulation of Various Designs — M. E. Vysotski · ENERGETIKA Proceedings of CIS higher education institutions and power engineering associations (2024) | TGRS Research Map | TGRS