Development of ZnFe(PBA)@Mo <sub>3</sub> C <sub>2</sub> T <sub>x</sub> Nanohybrid based Non‐Enzymatic Sensor for the Detection of Glucose in Human Sweat

Abstract ZnFe (PBA)@Mo 3 C 2 T x is prepared by in‐situ sonication method using ZnFe Prussian blue analogue infused with Mo 3 C 2 T x (MXene) to use as a non‐enzymatic glucose sensor owing to its low cost and biocompatibility. The synthesized ZnFe (PBA)@Mo 3 C 2 T x is characterized for its physical and chemical characterization by XRD, Raman, XPS, EDAX, and FESEM analyses, revealing a functionalized multiple‐layered structure with a cubic nano‐hybrid arrangement. This sensor has undergone electroanalytical investigation, including cyclic voltammetry and chronoamperometry analysis. The electrochemical performance of ZnFe(PBA)@Mo 3 C 2 T x exhibits an excellent analytical performance with a sensitivity of 818.285 μA mM −1 cm −2 and the limit of detection (LOD) of 1.6 μM (S/N=3). The analysis of glucose in human sweat samples, compared with their corresponding blood glucose values, yield a relative standard deviation (RSD) of 2.98 %.

Authors

Institutions

Publication Details

Journal
ChemistrySelect
Published
2024-08-16
DOI
https://doi.org/10.1002/slct.202401553
Citations
6
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
1.25
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of ZnFe(PBA)@Mo 3 C 2 T x Nanohybrid based Non‐Enzymatic Sensor for the Detection of Glucose in Human Sweat

Rajaram Rajamohan, Mohamad S. AlSalhi, Subramania Angaiah, Saradh Prasad et al.
6 citations
ChemistrySelect
Electrochemical sensors and biosensors
1.25
article

Development of ZnFe(PBA)@Mo 3 C 2 T x Nanohybrid based Non‐Enzymatic Sensor for the Detection of Glucose in Human Sweat

Rajaram Rajamohan, Mohamad S. AlSalhi, Subramania Angaiah, Saradh Prasad, Preethi Dhandapani, Arrthi Ravitchandiran
article en
6 citations

Abstract

Abstract ZnFe (PBA)@Mo 3 C 2 T x is prepared by in‐situ sonication method using ZnFe Prussian blue analogue infused with Mo 3 C 2 T x (MXene) to use as a non‐enzymatic glucose sensor owing to its low cost and biocompatibility. The synthesized ZnFe (PBA)@Mo 3 C 2 T x is characterized for its physical and chemical characterization by XRD, Raman, XPS, EDAX, and FESEM analyses, revealing a functionalized multiple‐layered structure with a cubic nano‐hybrid arrangement. This sensor has undergone electroanalytical investigation, including cyclic voltammetry and chronoamperometry analysis. The electrochemical performance of ZnFe(PBA)@Mo 3 C 2 T x exhibits an excellent analytical performance with a sensitivity of 818.285 μA mM −1 cm −2 and the limit of detection (LOD) of 1.6 μM (S/N=3). The analysis of glucose in human sweat samples, compared with their corresponding blood glucose values, yield a relative standard deviation (RSD) of 2.98 %.

ChemistrySelectVol. 9(31)
Pondicherry University (IN), King Saud University (SA), Yeungnam University (KR)
Openalex Percentile: Top 20%
Electrochemical sensors and biosensors
1.25
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Development of ZnFe(PBA)@Mo <sub>3</sub> C <sub>2</sub> T <sub>x</sub> Nanohybrid based Non‐Enzymatic Sensor for the Detection of Glucose in Human Sweat — Rajaram Rajamohan, Mohamad S. AlSalhi, et al. · ChemistrySelect (2024) | TGRS Research Map | TGRS