Highly Sensitive D-SPR Sensors with Optimized Metallic Thin Films for Bio-Analyte Detection

There is a growing need for precise and rapid detection methods in fields such as biomedical diagnostics, environmental monitoring, and chemical analysis. Surface plasmon resonance (SPR) sensors have been used for the detection and quantification of a wide range of analytes, including biomolecules, chemicals, and gases, in real-time. Despite the promising capabilities of SPR sensors, there remains a gap in creating a balance between having a large enough area to capture a significant number of analytes for detection and being small enough to ensure high sensitivity. This research aims to explore the design of a D-shaped SPR-based optical fiber sensor, focusing on the use of copper, gold, and silver thin films at optimized width and thickness of 10 µm and 45 nm, respectively, to improve the sensor’s performance. Employing a computational approach, this study examines the influence of the optimized width and refractive indices of metallic films on the sensor’s characteristics. The 10 µm width of the metallic thin film has been found to produce an optimal balance between the sensitivity and the dynamic range of the sensor. Leveraging on the ratio of the real and imaginary parts of the dielectric constant of the thin film metal provides insight into the optical properties and sensitivity at certain wavelengths. Within an analyte refractive index range of 1.37–1.42 and a wavelength range of 650–1200 nm, results indicate that silver outperforms gold and copper at the optimized width with a wavelength sensitivity, and detection accuracy of 12,300 nmRIU−1, and 3.075, respectively. By optimizing the width of the metal thin film at 10 µm, a highly sensitive D-SPR is designed, allowing for enhanced sensor detection capabilities for a wide range of bioanalytes.

Authors

Institutions

Publication Details

Journal
Photonics
Published
2024-08-15
DOI
https://doi.org/10.3390/photonics11080764
Citations
4
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.94

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Highly Sensitive D-SPR Sensors with Optimized Metallic Thin Films for Bio-Analyte Detection

Somasundar Kannan, J. C. Ehiabhili, Radhakrishna Prabhu
4 citations
Photonics
Advanced biosensing and bioanalysis techniques
0.94
article

Highly Sensitive D-SPR Sensors with Optimized Metallic Thin Films for Bio-Analyte Detection

Somasundar Kannan, J. C. Ehiabhili, Radhakrishna Prabhu
article en
4 citations

Abstract

There is a growing need for precise and rapid detection methods in fields such as biomedical diagnostics, environmental monitoring, and chemical analysis. Surface plasmon resonance (SPR) sensors have been used for the detection and quantification of a wide range of analytes, including biomolecules, chemicals, and gases, in real-time. Despite the promising capabilities of SPR sensors, there remains a gap in creating a balance between having a large enough area to capture a significant number of analytes for detection and being small enough to ensure high sensitivity. This research aims to explore the design of a D-shaped SPR-based optical fiber sensor, focusing on the use of copper, gold, and silver thin films at optimized width and thickness of 10 µm and 45 nm, respectively, to improve the sensor’s performance. Employing a computational approach, this study examines the influence of the optimized width and refractive indices of metallic films on the sensor’s characteristics. The 10 µm width of the metallic thin film has been found to produce an optimal balance between the sensitivity and the dynamic range of the sensor. Leveraging on the ratio of the real and imaginary parts of the dielectric constant of the thin film metal provides insight into the optical properties and sensitivity at certain wavelengths. Within an analyte refractive index range of 1.37–1.42 and a wavelength range of 650–1200 nm, results indicate that silver outperforms gold and copper at the optimized width with a wavelength sensitivity, and detection accuracy of 12,300 nmRIU−1, and 3.075, respectively. By optimizing the width of the metal thin film at 10 µm, a highly sensitive D-SPR is designed, allowing for enhanced sensor detection capabilities for a wide range of bioanalytes.

PhotonicsVol. 11(8)
Robert Gordon University (GB)
Robert Gordon University
Openalex Percentile: Top 26%
Advanced biosensing and bioanalysis techniques
0.94
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.