Influence of Anticoagulants on the Dissociation of Cardiac Troponin Complex in Blood Samples

Immunodetection of cardiac isoforms of troponin I (cTnI) and troponin T (cTnT) in blood samples is widely used for the diagnosis of acute myocardial infarction. The cardiac troponin complex (ITC-complex), comprising cTnI, cTnT, and troponin C (TnC), makes up a large portion of troponins released into the bloodstream after the necrosis of cardiomyocytes. However, the stability of the ITC-complex has not been fully investigated. This study aimed to investigate the stability of the ITC-complex in blood samples. A native ITC-complex was incubated in buffer solutions, serum, and citrate, heparin, or EDTA plasma at various temperatures. Western blotting and gel filtration were performed, and troponins were detected using specific monoclonal antibodies. The ITC-complex dissociated at 37 °C in buffers with or without anticoagulants, in citrate, heparin, and EDTA plasmas, and in serum, into a binary cTnI-TnC complex (IC-complex) and free cTnT. In plasma containing heparin and EDTA, the IC-complex further dissociated into free TnC and cTnI. No dissociation was found at 4 °C or at room temperature (RT) in all matrices within 24 h except for EDTA plasma. After incubation at 37 °C in EDTA plasma and serum, dissociation was accompanied by proteolytic degradation of both cTnI and cTnT. The presence of anti-troponin autoantibodies in the sample impeded dissociation of the ITC-complex. The ITC-complex dissociates in vitro to form the IC-complex and free cTnT at 37 °C but is mostly stable at 4 °C or RT. Further dissociation of the IC-complex occurs at 37 °C in plasmas containing heparin and EDTA.

Authors

Institutions

Publication Details

Journal
International Journal of Molecular Sciences
Published
2024-08-16
DOI
https://doi.org/10.3390/ijms25168919
Citations
7
Primary Topic
Acute Myocardial Infarction Research
Type
article
Field-Weighted Citation Impact
2.81
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of Anticoagulants on the Dissociation of Cardiac Troponin Complex in Blood Samples

Alexandra V. Vylegzhanina, Alexander E Kogan, Agnessa P. Bogomolova, A. Bereznikova et al.
7 citations
International Journal of Molecular Sciences
Acute Myocardial Infarction Research
2.81
article

Influence of Anticoagulants on the Dissociation of Cardiac Troponin Complex in Blood Samples

Alexandra V. Vylegzhanina, Alexander E Kogan, Agnessa P. Bogomolova, A. Bereznikova, Д. В. Певзнер, Natalia S. Riabkova, Ivan A. Katrukha, Amina K. Alieva, Alexey G Katrukha
article en
7 citations

Abstract

Immunodetection of cardiac isoforms of troponin I (cTnI) and troponin T (cTnT) in blood samples is widely used for the diagnosis of acute myocardial infarction. The cardiac troponin complex (ITC-complex), comprising cTnI, cTnT, and troponin C (TnC), makes up a large portion of troponins released into the bloodstream after the necrosis of cardiomyocytes. However, the stability of the ITC-complex has not been fully investigated. This study aimed to investigate the stability of the ITC-complex in blood samples. A native ITC-complex was incubated in buffer solutions, serum, and citrate, heparin, or EDTA plasma at various temperatures. Western blotting and gel filtration were performed, and troponins were detected using specific monoclonal antibodies. The ITC-complex dissociated at 37 °C in buffers with or without anticoagulants, in citrate, heparin, and EDTA plasmas, and in serum, into a binary cTnI-TnC complex (IC-complex) and free cTnT. In plasma containing heparin and EDTA, the IC-complex further dissociated into free TnC and cTnI. No dissociation was found at 4 °C or at room temperature (RT) in all matrices within 24 h except for EDTA plasma. After incubation at 37 °C in EDTA plasma and serum, dissociation was accompanied by proteolytic degradation of both cTnI and cTnT. The presence of anti-troponin autoantibodies in the sample impeded dissociation of the ITC-complex. The ITC-complex dissociates in vitro to form the IC-complex and free cTnT at 37 °C but is mostly stable at 4 °C or RT. Further dissociation of the IC-complex occurs at 37 °C in plasmas containing heparin and EDTA.

International Journal of Molecular SciencesVol. 25(16)
Lomonosov Moscow State University (RU), HyTest (Finland) (FI), National Medical Research Center of Cardiology (RU)
Openalex Percentile: Top 8%
Acute Myocardial Infarction Research
2.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.