Linear Actuators Based on Polyvinyl Alcohol/Lithium Chloride Hydrogels Activated by Low AC Voltage

The development of fast-responding electrically conductive polymers as actuators activated by low electrical current is now regarded as an urgent matter. Due to their limited electrical conductivity, actuators based on polymeric hydrogels must be activated using a high voltage (up to 200 V) and frequency (up to 500 Hz) when employing AC power. In this work, to improve the electrical conductivity of the hydrogel and decrease the required activation voltage of the hydrogel actuators, lithium chloride (LiCL) was added as a conductive filler to the polymer matrix of polyvinyl alcohol (PVA). In order to ascertain the deformation of actuators, activation and relaxation times, actuator efficiencies, and generated force under the conditions of activation, linear actuators that can be activated by extension/contraction (swelling/shrinking) cycles were prepared and investigated depending on the LiCl content, applied voltage, and frequency. Under a load of approximately 20 kPa and using a 90 V AC power at a 50 Hz frequency with a 30 wt.% LiCl content, it was found that the actuators’ total contraction, reinforced by a woven mesh braided material, was about 20% with a ~2.2 s activation time, while the actuators’ total extension, reinforced by a spiral weave material, was about 52% with a ~2.5 s activation time, after applying a 110 V AC at a 50 Hz frequency with a 10 wt.% LiCl content. Furthermore, as the lowest voltage, a 20 V AC power can operate these actuators by increasing the LiCl weight content to the same PVA mass content. Moreover, the PVA/LiCl hydrogels’ activation force can be greater than 0.5 MPa. The actuators that have been developed have broad applications in soft robotics, artificial muscles, medicine, and aerospace fields.

Authors

Institutions

Publication Details

Journal
Journal of Composites Science
Published
2024-08-15
DOI
https://doi.org/10.3390/jcs8080323
Citations
2
Primary Topic
Advanced Materials and Mechanics
Type
article
Field-Weighted Citation Impact
0.43
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Linear Actuators Based on Polyvinyl Alcohol/Lithium Chloride Hydrogels Activated by Low AC Voltage

P. V. Zhemchugov, Tarek Dayyoub, Aleksey V. Maksimkin, M.Yu. Zadorozhnyy et al.
2 citations
Journal of Composites Science
Advanced Materials and Mechanics
0.43
article

Linear Actuators Based on Polyvinyl Alcohol/Lithium Chloride Hydrogels Activated by Low AC Voltage

P. V. Zhemchugov, Tarek Dayyoub, Aleksey V. Maksimkin, M.Yu. Zadorozhnyy, D. V. Telyshev, Kseniia V. Filippova, Lidiia D. Iudina, Dmitriy G. Ladokhin
article en
2 citations

Abstract

The development of fast-responding electrically conductive polymers as actuators activated by low electrical current is now regarded as an urgent matter. Due to their limited electrical conductivity, actuators based on polymeric hydrogels must be activated using a high voltage (up to 200 V) and frequency (up to 500 Hz) when employing AC power. In this work, to improve the electrical conductivity of the hydrogel and decrease the required activation voltage of the hydrogel actuators, lithium chloride (LiCL) was added as a conductive filler to the polymer matrix of polyvinyl alcohol (PVA). In order to ascertain the deformation of actuators, activation and relaxation times, actuator efficiencies, and generated force under the conditions of activation, linear actuators that can be activated by extension/contraction (swelling/shrinking) cycles were prepared and investigated depending on the LiCl content, applied voltage, and frequency. Under a load of approximately 20 kPa and using a 90 V AC power at a 50 Hz frequency with a 30 wt.% LiCl content, it was found that the actuators’ total contraction, reinforced by a woven mesh braided material, was about 20% with a ~2.2 s activation time, while the actuators’ total extension, reinforced by a spiral weave material, was about 52% with a ~2.5 s activation time, after applying a 110 V AC at a 50 Hz frequency with a 10 wt.% LiCl content. Furthermore, as the lowest voltage, a 20 V AC power can operate these actuators by increasing the LiCl weight content to the same PVA mass content. Moreover, the PVA/LiCl hydrogels’ activation force can be greater than 0.5 MPa. The actuators that have been developed have broad applications in soft robotics, artificial muscles, medicine, and aerospace fields.

Journal of Composites ScienceVol. 8(8)
National University of Science and Technology (RU), Sechenov University (RU), National Research University of Electronic Technology (RU)
Affordable and clean energy
Openalex Percentile: Top 43%
Advanced Materials and Mechanics
0.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.