Calibration techniques for Thomson scattering diagnostics on large fusion experiments

Larger fusion experiments require long beam paths for laser diagnostics, which requires mechanical stability and measures to deal with remaining alignment variations. At the same time, due to technical and organizational boundary conditions, calibrations become challenging. The current mid-sized experiments face the same issues, yet on a smaller scale, which makes them ideal testing environments for novel calibration methods, since a comparison with the established best practices is still possible. At the stellarator Wendelstein 7-X, the calibration and operation of the Thomson scattering diagnostic is hampered by beam displacements, coating of windows during operation, and access restrictions while the superconducting coils are active. New calibration techniques were developed to improve the profile quality and reduce calibration time. While positional variations of the laser beam have to be minimized, the remaining displacements can be accounted for during the absolute calibration. An in situ spectral calibration has been developed based on Rayleigh scattering, which calibrates the whole diagnostic, including observation windows. In addition, a less accurate but faster method has been developed, which utilizes stray-light of a tunable OPO to perform spectral calibration within minutes and does not require torus hall access. Finally, a workflow has been established to consider finite linewidths of the calibration source in the spectral calibration. While these methods will be used at W7-X to complement existing calibration techniques, they may also solve some of the aforementioned issues expected for even larger and nuclear experiments, where access restrictions are stringent and calibration becomes even more demanding.

Authors

Institutions

Publication Details

Journal
Review of Scientific Instruments
Published
2024-08-01
DOI
https://doi.org/10.1063/5.0219161
Citations
3
Primary Topic
Magnetic confinement fusion research
Type
article
Field-Weighted Citation Impact
1.98

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Calibration techniques for Thomson scattering diagnostics on large fusion experiments

K. J. Brunner, S. Bozhenkov, M. Hirsch, J. M. Frank et al.
3 citations
Review of Scientific Instruments
Magnetic confinement fusion research
1.98
article

Calibration techniques for Thomson scattering diagnostics on large fusion experiments

K. J. Brunner, S. Bozhenkov, M. Hirsch, J. M. Frank, J.S. Wagner, J. Knauer, R. C. Wolf, G. Fuchert, M. Beurskens, L. V. Henschke, S. Chen, E. Pasch
article en
3 citations

Abstract

Larger fusion experiments require long beam paths for laser diagnostics, which requires mechanical stability and measures to deal with remaining alignment variations. At the same time, due to technical and organizational boundary conditions, calibrations become challenging. The current mid-sized experiments face the same issues, yet on a smaller scale, which makes them ideal testing environments for novel calibration methods, since a comparison with the established best practices is still possible. At the stellarator Wendelstein 7-X, the calibration and operation of the Thomson scattering diagnostic is hampered by beam displacements, coating of windows during operation, and access restrictions while the superconducting coils are active. New calibration techniques were developed to improve the profile quality and reduce calibration time. While positional variations of the laser beam have to be minimized, the remaining displacements can be accounted for during the absolute calibration. An in situ spectral calibration has been developed based on Rayleigh scattering, which calibrates the whole diagnostic, including observation windows. In addition, a less accurate but faster method has been developed, which utilizes stray-light of a tunable OPO to perform spectral calibration within minutes and does not require torus hall access. Finally, a workflow has been established to consider finite linewidths of the calibration source in the spectral calibration. While these methods will be used at W7-X to complement existing calibration techniques, they may also solve some of the aforementioned issues expected for even larger and nuclear experiments, where access restrictions are stringent and calibration becomes even more demanding.

Review of Scientific InstrumentsVol. 95(8)
Max Planck Institute for Plasma Physics - Greifswald (DE), Technische Universität Berlin (DE), Technical University of Munich (DE)
EUROfusion
Openalex Percentile: Top 9%
Magnetic confinement fusion research
1.98
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.