A 44-cm3 physics package for the high-performance pulsed optically pumped atomic clock

The pulsed optically pumped (POP) atomic clock has demonstrated unexpected performance in terms of frequency stability and drift. However, it remains a huge challenge to make this type of atomic clock more compact. Herein, we report the design of a miniaturized physics package, which is equipped with a magnetron microwave cavity holding a vapor cell of 1.3 cm internal diameter. The Zeeman transition spectrum reveals that the microwave cavity resonates in TE011-like mode. Based on a low-noise testbed, we also quantitatively analyze the relaxation time, linewidth, and noise sources of the resulting POP atomic clock. The population and coherence relaxation time are measured to be 3.16(0.16) and 2.97(0.03) ms under the temperature of 333 K, which are compatible well with the theoretical calculation. The Ramsey signal shows a contrast of 35% and a linewidth of 192 Hz. The total volume of the physics package is about 44 cm3, including a layer of magnetic shielding. The short-term frequency stability is measured to be 4.8 × 10-13τ-1/2 (where τ is the averaging time), which is mainly limited by the relative intensity noise of the laser system.

Authors

Institutions

Publication Details

Journal
Review of Scientific Instruments
Published
2024-08-01
DOI
https://doi.org/10.1063/5.0219868
Citations
3
Primary Topic
Atomic and Subatomic Physics Research
Type
article
Field-Weighted Citation Impact
1.01

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A 44-cm3 physics package for the high-performance pulsed optically pumped atomic clock

Peter Yun, Shougang Zhang, Qiang Hao, Shaojie Yang et al.
3 citations
Review of Scientific Instruments
Atomic and Subatomic Physics Research
1.01
article

A 44-cm3 physics package for the high-performance pulsed optically pumped atomic clock

Peter Yun, Shougang Zhang, Qiang Hao, Shaojie Yang, Jun Ruan, Shuguang Zheng
article en
3 citations

Abstract

The pulsed optically pumped (POP) atomic clock has demonstrated unexpected performance in terms of frequency stability and drift. However, it remains a huge challenge to make this type of atomic clock more compact. Herein, we report the design of a miniaturized physics package, which is equipped with a magnetron microwave cavity holding a vapor cell of 1.3 cm internal diameter. The Zeeman transition spectrum reveals that the microwave cavity resonates in TE011-like mode. Based on a low-noise testbed, we also quantitatively analyze the relaxation time, linewidth, and noise sources of the resulting POP atomic clock. The population and coherence relaxation time are measured to be 3.16(0.16) and 2.97(0.03) ms under the temperature of 333 K, which are compatible well with the theoretical calculation. The Ramsey signal shows a contrast of 35% and a linewidth of 192 Hz. The total volume of the physics package is about 44 cm3, including a layer of magnetic shielding. The short-term frequency stability is measured to be 4.8 × 10-13τ-1/2 (where τ is the averaging time), which is mainly limited by the relative intensity noise of the laser system.

Review of Scientific InstrumentsVol. 95(8)
Chinese Academy of Sciences (CN), National Time Service Center (CN), University of Chinese Academy of Sciences (CN)
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 25%
Atomic and Subatomic Physics Research
1.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.