Performance testing of a novel angle comparator with inner and outer shafts

Abstract The angle comparator is a key device for calibrating angle devices, and its performance seriously affects the accuracy of angle calibration. In order to achieve high-precision angle reproduction, a new type of inner and outer axis angle comparator was developed, its angle measurement performance was tested, and the diagonal position error was compensated. Firstly, the structure of an internal and external axis angle comparator based on dual drive of ultrasonic motor and torque motor is briefly introduced. Then, the external cross-calibration method for the full fillet position error of the angle comparator and the testing and evaluation method for motion resolution were studied. Finally, the angle measurement performance of the angle comparator was tested and compensated, and the measurement results were analyzed and verified. The experimental results show that the compensated internal and external axis angle comparator has an angular position error of 0.08”, a measurement uncertainty of 0.03” ( k =2), and a motion resolution of 0.018”, indicating that the developed instrument has a stable high-precision calibration ability in the sub arc-second level.

Authors

Publication Details

Journal
Journal of Physics Conference Series
Published
2024-08-01
DOI
https://doi.org/10.1088/1742-6596/2825/1/012033
Citations
3
Primary Topic
Advanced Measurement and Metrology Techniques
Type
article
Field-Weighted Citation Impact
0.64
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance testing of a novel angle comparator with inner and outer shafts

Qiang Tang, Yangqiu Xia, Long Chen, Qiang Li et al.
3 citations
Journal of Physics Conference Series
Advanced Measurement and Metrology Techniques
0.64
article

Performance testing of a novel angle comparator with inner and outer shafts

Qiang Tang, Yangqiu Xia, Long Chen, Qiang Li, Mengyang Li
article en
3 citations

Abstract

Abstract The angle comparator is a key device for calibrating angle devices, and its performance seriously affects the accuracy of angle calibration. In order to achieve high-precision angle reproduction, a new type of inner and outer axis angle comparator was developed, its angle measurement performance was tested, and the diagonal position error was compensated. Firstly, the structure of an internal and external axis angle comparator based on dual drive of ultrasonic motor and torque motor is briefly introduced. Then, the external cross-calibration method for the full fillet position error of the angle comparator and the testing and evaluation method for motion resolution were studied. Finally, the angle measurement performance of the angle comparator was tested and compensated, and the measurement results were analyzed and verified. The experimental results show that the compensated internal and external axis angle comparator has an angular position error of 0.08”, a measurement uncertainty of 0.03” ( k =2), and a motion resolution of 0.018”, indicating that the developed instrument has a stable high-precision calibration ability in the sub arc-second level.

Journal of Physics Conference SeriesVol. 2825(1)
Affordable and clean energy
Openalex Percentile: Top 36%
Advanced Measurement and Metrology Techniques
0.64
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Performance testing of a novel angle comparator with inner and outer shafts — Qiang Tang, Yangqiu Xia, et al. · Journal of Physics Conference Series (2024) | TGRS Research Map | TGRS